* CorePace Module 4: Troubleshooting If a pacemaker is oversensing, you will see signals on the marker channel that do not correspond to the ECG pattern. In this example, the pacemaker recorded a ventricular pulse on the marker channel. However, no activity was demonstrated on the ECG strip. Pauses or intervals longer than the programmed lower rate will occur in single chamber systems. Dual chamber systems may show tracking at the upper rate with atrial oversensing. This ECG exhibits oversensing that may be attributed to: Lead insulation failure (a decrease in lead impedance will be seen) Make-and-break fracture A lead connection problem (Note: The information below transitions into the next slide.) Insulation failure梐 common cause of oversensing梠ccurs when myopotentials are detected at the site of the insulation break. Lead fracture is another common cause of oversensing. As the frayed ends of conductor wires 搈ake and break?contact, the pacemaker senses these 搈ake and break?signals, which results in oversensing. Oversensing may also occur if the lead is loose in the connector block. * CorePace Module 4: Troubleshooting Interference falls under two categories: Electromagnetic interference (EMI) Skeletal myopotentials (noncardiac signals) Oversensing may occur when EMI signals are incorrectly interpreted as P- orR-waves. Sources of EMI are often found in hospitals and include surgical/therapeutic equipment, such as: Electrocautery Transthoracic defibrillation Lithotripsy RF ablation TENS units MRI is generally contraindicated for pacemaker patients. Exposure to a magnetic field may produce high-rate pacing that results in ventricular fibrillation and may damage the circuitry of the device. Concomitant devices, such as ICDs, should be tested to ensure that oversensing between the two devices does not occur. The most common type of myopotential interference is the inappropriate inhibition of pacing pulses as a result of the sensing of myopotentials. Myopotential
您可能关注的文档
- 课件:鼻咽癌放疗个案护理.ppt
- 课件:鼻咽癌合并放化疗治疗患者的护理.ppt
- 课件:病历书写.ppt
- 课件:产科学基础正常产褥.ppt
- 课件:常见微生物性食物中毒.ppt
- 课件:常用机床电气控制.ppt
- 课件:超声诊断基础.ppt
- 课件:超早期脑梗死的CT影像表现及诊断.ppt
- 课件:成骨性骨转移瘤.ppt
- 课件:成人术后疼痛处理专家共识解读.ppt
- 2025北京航空工业集团综合所高层次人才及博士招聘20人笔试参考题库附答案.docx
- 2025安徽亳州市利辛县巡察信息中心遴选5人备考题库附答案.docx
- 2025宁波鄞州区东柳街道编外招聘1人备考题库附答案.docx
- 2025云南楚雄市机关事业单位选调63人备考题库附答案.docx
- 2025北京中国社会科学调查中心招聘劳动合同制人员1人备考题库附答案.docx
- 2025宁波市市场监督管理局局属事业单位宁波市标准化研究院招聘高层次人才1人备考题库附答案.docx
- 2025河南郑州铁路职业技术学院招聘合同制工作人员48人笔试历年题库附答案解析.docx
- 2025云南玉溪市红塔区文化和旅游局招聘办公辅助人员1人备考题库附答案.docx
- 2025山东日照市岚山区卫生健康系统事业单位招聘20人备考题库附答案.docx
- 2025四川九州电子科技股份有限公司招聘车载电子事业部-PQE岗笔试参考题库附答案.docx
最近下载
- 2023年资料员资格考试题库附参考答案(完整版).docx
- GJB438C-2024军用软件开发文档通用要求(高清,带章).pptx VIP
- 新高考3+1+2政策解读及选科指导+课件--2025-2026学年高一上学期生涯规划主题班会.pptx
- 2023《BIM工程师》继续教育题库及参考答案【夺分金卷】.docx
- 部编版道德与法治四年级上册《3我们班 他们班》教学反思(两篇).pdf
- 内科学 脑梗死 脑血栓形成.ppt VIP
- 2021年七年级生物上册单元测试定心卷:第二单元 探索生命(能力提升)(苏教版教师版).pdf VIP
- 部编版道德与法治五年级上册《5协商决定班级事务》教学反思(两篇).pdf
- 大学生心理健康 第3章-教学教案-自我意识.docx VIP
- 2023年心理咨询师考试题库含答案(满分必刷).docx
原创力文档


文档评论(0)