DNA甲基化检测技术解读.pptVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
感谢聆听! THANK YOU FOR WATCHING! 演示结束! * Part 2 of our afternoon double feature is the instrumentation aspect of this amplicon melting application. We currently have 2 instruments designed specifically for Hi-Res melting, … the LightScanner and the HR-1. The LightScanner is available in a 96 or 384 well format. The heat block used is compatible with almost any currently available microtiter plate used on a variety of block style thermal cyclers. Melt time is approximately 5 minutes per plate which gives melting curve results on all of the samples in the plate. Just to be clear, 5 minutes of melting gives you 96 or 384 results, which is approximately 4 seconds per sample in a 96 well plate, and 1 second per sample in a 384 well plate. The heat block in the LightScanner is capable of maintaining a +/- 0.2 degree difference between wells across the plate, which is pretty good considering even the most accurate thermal block cyclers typically are capable of maintaining only a +/- 1 degree difference across the plate. At a thermal ramp rate of 0.15 degrees/second, the LightScanner collects 20 data points per degree. The HR-1 is a single sample instrument, designed around amplification in a LightCycler capillary. The HR-1 accepts the capillary in a custom designed heating element called an “ingot”. Basically, the ingot is made of a highly conductable metal that is wrapped in a heat coil such that there is no detectable temperature gradient from top to bottom or side to side in the capillary. This assures temperature homogeneity within the sample and a more accurate depiction of what is happening to the sample as it is melted. Scanning of a single sample takes approximately 30 seconds in the HR-1, and the optics are custom designed for the LCGreen dye. As I mentioned, the ingot design is capable of maintaining at least a +/- 0.05 degree intra- and inter-run temperature difference, and may actually be better than that, but 0.05 degrees is the limit of what we could acc

文档评论(0)

文档分享 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档