溶液预处理空气源热泵供热系统性能初步分析
摘要:通过对比现有的空气源热泵空调系统的优缺点,提出了一种溶液预处理空气源热泵供热系统。通过对该系统务个 运行模式建立系统性能模型,综合分析该新型洛液预处理空气源热泵空调系统在冬季工况下的系统性能,得出该新型洛液 预处理空气源热泵空调系统在0°C相对湿度60%的工况下系统COP可达3. 30,而在-7°C-5. 5°C相对湿度60%的工况下,系 统的COP在3. 10-3. 42 Z间,比传统的电融霜空气源热泵系统COP高,传统的电融霜空气源热泵系统的COP大约为2。 关键词:热泵;无霜;供热系统;除湿系统
Performance analysis of a new type of air source heat pump heatingsystem based on liquid desiccant dehumidification
Li Weihao, Zhang Xiaosong
(School of Energy and Environment, Southeast University, Nanjing 210096, Jiangsu, China)
Abstract: This paper reports a performanee analysis for a new type of air source heat pump heating system? There are two operational mode in this system including supply heat mode and regeneration mode .In supply heat mode, the latent heat load is treated by liquid desiccant tower; the sensible heat load is treated by liquid desiccant tower and fin-tube coil evaporator; airflow become dry when it crows the liquid desiccant tower, frosting can be retarded. In regeneration mode, the liquid desiccant tower becomes condenser, and system is a closed loop, the airflow circulation in the flow of dry and wet state. Through setting up model, the overall system performance was analyzed at a dry-bulb temperature of -7°C-5.5°C and a relative humidity of 60%-80% depending on the frosting condition. the results show that the coefficient of performance up to 3.30 at a dry-bulb temperature of 0°C and a relative humidity of 60% condition, and the coefficient of performance is with the range 3.10-3.42 at a dry-bulb temperature of -7°C-5.5°C and a relative humidity of 60% which is higher than that traditional air condition system which coefficient of performanee is about 2.
Key words: heat pump; no-frost; heating system; desiccant system
0 前言
目前建筑能耗占中国全社会能耗的27. 5%,而空调系统的能耗占建筑能耗的主要部分,随着城镇化快 速发展,生活水平的提高,对空调节能产生巨大压力,寻找一种高效节能安全环保的新型空调系统是解决 这一问题的重要途径。传统的空气源热泵机组采用翅片管换热器与空气换热,但是当温度过低时蒸发器
基金项目:国家自然科学国际合作基金)()9)。
表面结霜换热条件恶化所以必须除霜,频繁的除霜会使系统功耗大幅上升,系统总效率不高目前针 对冬季供热问题,学者们提出了多种解决办法。通过对空气源