基于全相位谱分析与滤波的新型心电检测软件系统的设计与实现-信息与通信工程专业论文.docxVIP

基于全相位谱分析与滤波的新型心电检测软件系统的设计与实现-信息与通信工程专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
ABSTRACT With the increase of patients in cardiovascular disease, coupled with the level of awareness of the increasing demand for health care, the traditional Holter detection technology has been unable to meet the requirements of the people. In recent years, the ECG detection technology is developing and improving constantly, but looking for more efficient and accurate ECG detection technology has been the researchers pursuit. ECG detection algorithm mainly includes two core parts which are ECG waveform detection and de-noising, and the technology is mainly reflected in ECG workstation system. Because ECG is always mixed with the baseline drift and frequency interference signals, which seriously affected the ECG waveform detection. Therefore, the primary goal of ECG detection technology is de-noising to obtain the pure ECG. To address this problem, this paper presented an efficient method to remove the baseline drift and frequency interference with FIR digital filter, which combination a high pass filter with cut-off frequency of 0.67Hz and a notch filter noising filter with frequency of 50Hz and its harmonics to achieve the purpose. Experiments show that, the high pass filter with frequency of 0.67Hz can completely filter the baseline drift of signal, and Saved multiplier of 94.35%, while the notch filter is able to remove the frequency of 50Hz and its harmonics in interference. Meanwhile, the combined filter has a good anti-noise performance, low computational complexity, and it is also very efficient and feasible. For the phenomenon of that frequency interference of the actual ECG signal is not always just at the frequency of 50Hz, this paper presents a novel method based on all phase filter design, the filter is combined with a 0.05Hz ~ 250Hz band-pass filter and a all phase notch filter in any point. The key technology is to estimate the exact frequency of interference, and design a all-phase specific frequency notch filter. Experiments show that the combina

您可能关注的文档

文档评论(0)

1234554321 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档