Ag和Ta离子双注入改善Ti6Al4V合金耐磨性能.pdf

45 6 Vol.45 No.6 2009 6 764—768 ACTA METALLURGICA SINICA Jun. 2009 pp.764–768 Ag Ta Ti6Al4V ∗ 1) 2) 3) 2) 2) 1) , 650093 2) , 650093 3) , 100875 Ag Ta Ti6Al4V , Ag 1.0×1017 cm−2 Ta 1.5× 1017 cm−2 . ℄ Ti6Al4V , , XRD XPS ℄. , 77%. , . Ti6Al4V, , , , TG146.2 A 0412−1961(2009)06−0764−05 WEAR PERFORMANCE OF Ti6Al4V ALLOY MODIFIED BY Ag+Ta DUAL–ION IMPLANTATION LENG Chongyan 1), ZHOU Rong 2), ZHANG Xu 3) , LU Dehong 2), LIU Hongxi 2) 1) School of Materials and Metallurgical Engineering, Kunming University of Science and Technology, Kunming 650093 2) School of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650093 3) Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing 100875 Correspondent: LENG Chongyan, associate professor, Tel: (0871)5136755, E-mail: lengchongyan22@ Manuscript received 2008–11–07, in revised form 2009–03–05 ABSTRACT The wear performance of Ti6Al4V alloy for clinical usage was modified by dual– ion implantation technique. The samples were implanted firstly with silver ions at a dose of 1.0 × 1017 cm−2 , then with tantalum ions at a dose of 1.5×1017 cm−2 . Nanoindenter instrument was used to measure the variation of hardness with displacement into surface of sample, and multi–functional tribological tester was used to investigate the wear and tribological property. Phase constitution in the surface layer of Ti6Al4V alloy was characterized by glancing angle X–ray diffraction (GAXRD), the X–ray photoelectron spectroscopy was used