三相四线制配电网静止同步补偿器的分析-电力系统及其自动化专业论文.docxVIP

三相四线制配电网静止同步补偿器的分析-电力系统及其自动化专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
哈尔滨工业大学工学硕士学位论文 哈尔滨工业大学工学硕士学位论文 - - II - Abstract In now days, due to the using of a huge number of nonlinear loads in the distribution network, the power quality of the three phase four-wire distribution system becomes more and more serious. Worse still, the zero sequence aggravates the complexity of this issue. So, it is in urgent need of deeply research. This article firstly introduces and analyzes the main power quality problems and existing solutions in three phase four-wire system. In these methods, compared with other types of compensation devices, distribution static synchronous compensator (DSTATCOM) has outstanding ability in solving the power equality problems, such as reactive power, harmonic, three-phase unbalance, voltage fluctuation and voltage flicker. Therefore this paper focuses on DSTATCOM in three-phase four-wire system. In this article, on base of introducing the main circuit topology structure of DSTATCOM in three-phase four –wire system, we get a four-bridge topology structure which could meet the requirements of compensating unbalance and outputting enough neutral current. Then its model is built. Control strategy of the DSTATCOM, especially the detection of compensation current, is also discussed emphatically in this paper. By analyzing the instantaneous reactive power theory based on the three-phase four-wire system, both of its superiorities and defects are got. According to its disadvantages, ip-iq-i0 detection method is improved. The validity of the improved method is demonstrated by simulation. PI controller is used in the voltage control of capacitor on DC side to get an outer voltage loop and an inner current feedback loop. The result of simulation indicates the correctness of the control strategy and the feasibility of the improved method. The choices of the capacity of devices and switching elements are also taken into account in this paper, such as the voltages and the capacity of devices on DC side and the value of connection indu

您可能关注的文档

文档评论(0)

peili2018 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档