SENTRY RS232 COMMUNICATION PROTOCOL
Index
General
TEXT MODE communication
BINARY MODE communication
TEXT MODE ups transmitted messages
BINARY MODE ups transmitted message
Easiest way to monitoring UPS status
How to get UPS shut-down
5 chars commands sequence
General
The communication with Sentry HPS/RPS use RS232serial line connection with:
only 3 wires TX , RX and GND;
8bits;
No parity;
Baud rate=9600 , selectable down to 1200 on the ups.
There are two ways to communicate; TEXT mode and BINARY mode.
Holding on “0” the ECHO function. As set in factory, the Sentry responds only after receiving a command char transmitted form computer.
If the ECHO is set on “1” when customizing some operating values, the Sentry transmits chars without receiving any command char from the computer..
With ECHO=1, each time that that the alarm condition changes, the Sentry transmits the “TEXT MESSAGE 9” without receiving any command.
TEXT MODE communication
The TEXT MODE communication is opened when computer transmits a sequence of two ASCII characters.
The first must be ‘9’ the second must be ‘0’ and in must be into the time interval of 0.5 – 2sec. after the first.
The second char is ‘0’ only id the customizing value “INDENT” is equal to ‘0’, as default, otherwise it must be equal to the new value of IDENT.
The IDENT value can be set from 0 to 7 to obtain the communication with 8 different machines connected to the same RE232 serial line.
After opening TEXT MODE communication the compute can send the ASCII chars form ‘1’ to ‘9’ to have back the “TEXT MESSAGES 9 ” and also to execute a command on the machine in the same of pushing the buttons panel numbered form 1 to 8.
Sending the char’9’, after the opening sequence, it is possible to obtain back the “TEXT MESSAGE 9” without execute any command on the machine, sending the ASCII char ‘:’ it is possible to receive the “TEXT MESSAGE :”.
The communication is CLOSED when sending any char different form ‘1’ to ‘9’ or ‘:’ and form three