技术与应用 影响电动机断路器动作高压同步电机变频节 能改造 陈建国 (湖南衡阳华菱钢管有限公司生产制造部,湖南衡阳 421001 ) 摘要 高压变频器在钢铁企业高压风机、水泵有了大量的应用。但高压同步电机变频调速 在全国应用实例不多,湖南衡阳华菱钢管有限公司敢为人先,2012 年 12 月对炼铁分厂180-烧结 主抽高压同步电机采用了高压变频器,同时改进了控制方式,节电可达 13%以上,取得很好的 经济效益。 关键词:同步电机;高压变频器;节能 Energy-saving High-voltage Synchronous Motor Chen Jianguo (Hu’nan Hengyang Valin Steel Tube Co., Ltd, Manufacturing Department of Hengyang, Hengyang, Hu’nan 421001) Abstract High voltage frequency converter is widely used in iron and steel enterprise high pressure fan, water pump. But high -voltage synchronous motor variable frequency speed regulation in the examples are not many, Hunan Valin Hengyang Steel Tube Co., dare be a person first, from 2012 December to Ironmaking Factory of 180 - sintering main high-voltage synchronous motor adopts high voltage frequency converter, and improved the control mode, the energy saving can reach 13%, can obtain very good economic benefits. Key words :synchronous motor ;high voltage frequency converter ;energy-saving 以减少溢流和节流损失,提高系统运行的经济性。 1 华菱衡钢炼铁分厂 180 烧结主抽除尘 现状及存在的问题 2 高压变频改造技术方案详述 1.1 炼铁分厂现场工况 2.1 高压变频器调速系统方案 目前炼铁180-烧结主抽除尘风机负载情况如表 1)考虑到炼铁生产高可靠性这一重要因素,作 1 所示。 出如下方案 1.2 存在的问题及其分析 采用 “一拖一加旁路”系统配置方式。改造后一 炼铁 180-烧结主抽除尘风机现状为:除尘风机 台高压变频拖动一台电机并配有旁路,变频器功率大 均采用风门调节方式,管网风阻增大,能源浪费严 冗余设计,系统配置大冗余设计,冗余量高。当变频 重。同步电机比异步电机多一励磁回路,调速相对 器发生故障时,可以工频起动风机系统,通过用户的 困难,为了确保生产,大部份企业都维持现状。随 集中控制系统或本机操作实现风机系统的起/停。保 着高压变频调速技术的日益成熟,我公司经反复论 证生产稳定运行。具体系统方案如图 1 所示。 证,决定采用变频调节方式对风机系统进行改造,