- 1、本文档共54页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
1. Relative humidity is often greater than 95%;Smokeless fire; 2.3 There is a lot of dust;4 Smoke and vapor retention under normal conditions;5 Kitchen, boiler room, generator room, drying workshop, etc.Smoking room, etc.;7 Other halls and public places where smoke detectors should not be installed. * The infrared light and ultraviolet light emitted by the fire detection flame are used to alarm.It is divided into infrared sensor and ultraviolet sensorApplication Place:1. There is strong flame radiation in fire;2 liquid combustion fire and other non-smoldering stage fire;The need for a quick response to the flame; * 1 Flameless fire may occur;2 There is smoke diffusion before the flame appears;3. The lens of the detector is easy to be polluted;4. The line of sight of the detector is easily blocked;5 The detector is susceptible to direct or indirect irradiation by sunlight or other light sources;6. Under normal conditions, there are open flame operations, X rays, arcs and other influences. * It can detect 2 or more fire parameters when a fire occurs, divided into 2 compound detector or 3 compound detector.According to the fire detection characteristics, it can be divided into smoke and temperature sensing type, temperature sensitive type, smoke sensitive type and infrared light beam smoke sensing type.The composite detector not only makes the performance more reliable, but also expands the application range of the detector and can be used in some special places. * 1. The horizontal distance between the detector and the wall and beam edge should not be less than 0.5m;2. There should be no occlusion within 0.5m around the detector;3. The horizontal distance between the detector and the air supply outlet of the air conditioner should not be less than 1.5m; The horizontal distance to the orifice of the porous air supply ceiling should not be less than 0.5m;4. When the detector is set on the ceiling of the inner walkway with a width less than 3m, it should be arranged in t
文档评论(0)