- 0
- 0
- 约4.9千字
- 约 3页
- 2026-01-23 发布于浙江
- 举报
MECHANICALENGINEERMECHANICALENGINEERMECHANICALE
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
MECHANICALENGINEER
机械工程师
MECHANICALENGINEER
运载火箭发动机电磁阀绝缘电阻超差问题分析
贾静雅,茹红宇,杜峻松,刘伟丽,王文斌,齐浩,张少星
(首都航天机械公司,北京100076)
摘要:在运载火箭发动机某次试车后的复测过程中,发现某电磁阀绝缘电阻下降,针对该情况,对电磁阀所用电磁铁进行了多余物、潮湿、接线片与壳体接触,以及线圈与壳体接触等四方面的分析和试验,结果表明,电磁阀绝缘下降是由多余物及潮湿两项因素共同导致,因此在后续的生产过程中,应严格控制接线板表面的质量,防止产生多余物。关键词:绝缘电阻下降;多余物;潮湿中图分类号:TH123.4 文献标志码:粤 文章编号:员园园圆原圆猿猿猿(202
摘要:在运载火箭发动机某次试车后的复测过程中,发现某电磁阀绝缘电阻下降,针对该情况,对电磁阀所用电磁铁进行了多余物、潮湿、接线片与壳体接触,以及线圈与壳体接触等四方面的分析和试验,结果表明,电磁阀绝缘下降是由多余物及潮湿两项因素共同导致,因此在后续的生产过程中,应严格控制接线板表面的质量,防止产生多余物。
关键词:绝缘电阻下降;多余物;潮湿
中图分类号:TH123.4 文献标志码:粤 文章编号:员园园圆原圆猿猿猿(2020)06原园112原园2
(CapitalAerospaceMachineryCorporationLimited,Beijing100076,China)
Keywords:Abstract:Duringtheretestafteratestrunofthelaunchvehicleengine,itwasfoundthattheinsulationresistanceofasolenoidvalvedecreased.Inviewofthissituation,theelectromagnetusedinthesolenoidvalvewasanalyzedandtestedinfouraspects,suchasexcess,humidity,contactbetweenthelugandthecase,andcontactbetweenthecoilandthecase.Theresultsindicatethattheinsulationdegradationofthesolenoidvalveiscausedbytheexce