国外标准分享ASTM E1390.docxVIP

  • 0
  • 0
  • 约9.79千字
  • 约 3页
  • 2026-03-10 发布于浙江
  • 举报

Designation:E1390–90(Reapproved2000)

StandardGuidefor

IlluminatorsUsedforViewingIndustrialRadiographs1

Thisstandardisissuedunderthe?xeddesignationE1390;thenumberimmediatelyfollowingthedesignationindicatestheyearof

originaladoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.A

superscriptepsilon(e)indicatesaneditorialchangesincethelastrevisionorreapproval.

1.Scope

sizeofthescreenshallallowtheusertoviewtheradiograph

withoutexcessiveglare.Iftheilluminatoristobeusedfor

viewingradiographsofvarioussizes,masksofvarioussizes

andcon?gurations,forexample,circularorrectangular,shall

beprovided.Alternately,anadjustableaperturemaybeused.

1.1Thisguideprovidestherecommendedminimumre-

quirementsforilluminatorsusedforviewingindustrial?lm

radiographsusingtransmittedlight.

1.2Theilluminatorhastoensurethesamesafetyfor

personnel,orusersofanyelectricapparatus,asspeci?edby

electricalstandardsapplicableinthecountryinwhichthe

illuminatorisused.

6.IlluminationRequirements3

6.1Luminance:

6.1.1Theluminance(orbrightness)ofthetransmittedlight

throughtheradiographshallnotbelessthan30cd/m2for?lm

densitiesequalorlessthan2.5,and10cd/m2for?lmdensities

greaterthan2.5.

2.ReferencedDocuments

2.1ASTMStandards:

E1316TerminologyforNondestructiveExaminations2

N

OTE

1—Wherepossible,approximately100cd/m2orhigherlumi-

nanceshouldbeused.

3.Terminology

3.1De?nitions—Forde?nitionsoftermsusedinthisguide,

seeTerminologyE1316.

6.1.2Toachievethemaximumluminancevalue,thatis,10

cd/m2,givenin6.1.1,theilluminatorbrightnessshallbeat

least105cd/m2.Thisshouldbedeterminedwithasuitably

calibratedphotometerortelephotometerplacedatthecenterof

theviewi