计量型测量系统研究记录(均值极差法)表1

零件

评价人/试验次数平均值

12345678910

1.A172.773.672.972.873.972.272.772.472.473.072.856

2.272.773.472.972.773.972.472.772.672.472.972.856

3.372.773.672.972.773.972.272.772.472.472.972.836

4.平均值72.6973.5172.9272.7673.8672.2672.7472.4472.3972.92Xa72.849

5.极差0.000.200.000.100.000.200.000.200.000.10Ra0.080

6.B172.773.372.972.773.972.272.772.472.472.972.806

7.272.773.672.872.773.972.272.772.472.472.972.826

8.372.773.672.972.773.972.472.772.472.472.972.856

9.平均值72.6973.4872.8872.7373.8672.2672.7472.3772.3972.89Xb72.829

10.极差0.000.300.100.000.000.200.000.000.000.00Rb0.060

11.C172.773.672.972.773.972.272.772.672.472.872.846

12.272.773.372.972.773.972.272.772.472.472.972.806

13.372.673.672.972.773.972.272.772.472.672.972.846

14.平均值72.6673.4872.9272.7373.8672.1972.7472.4472.4672.86Xc72.833