栓钉连接件极限承载力及剪切刚度的试验

* 周 安 戴 航 刘其伟 ( 230009) ( 210096) : ,, , ,,; , , : EXPERIMENT ON ULTIMATE BEARING CAPACITY AND SHEAR RIGIDITY OF STUD CONNECTORS Zhou An aiHang Liu Qiwei (Hefei University of Technology Hefei 230009) (Southeast University Nanjing 210096) Abstract : Based on 3 factors of stud diameter and concrete intensity and steel fibre, orthogonal push-off tests of welded stud shear connectorswere conducted. The analysis of range and variance shows that the steel fiber inside concrete has no effect on ultimate carrying capacity and shear rigidity of stud. Shear rigidity of stud increases as concrete intensity. The relation between shear rigidity and slip is hyperbolic function. Formulae calculating ultimate carrying capacity and shear rigidity of stud are given. The repeat load tests show that the slip is no comeback with unloading even if low-shear. Keyw rds : stud connectors ultimate carrying capacity shear rigidity orthogonal test , , : , ; , , , , , , , ; , , ,, - , , [ 1- 6] , ,- Ollgaard ; Fisher - : N = N c #( 1- ; / 0 (GB 50017- 2003) v u - 18$ 2P5 c e ) Buttry - : N v = N u # , 3115 $ , , 1+ 3115$, , N v , kN; $