intrinsic viscosity- louisiana state university(特性粘度路易斯安那州立大学).docVIP

intrinsic viscosity- louisiana state university(特性粘度路易斯安那州立大学).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
intrinsic viscosity- louisiana state university(特性粘度路易斯安那州立大学)

Intrinsic Viscosity Introduction One of the most precise measurements in polymer science is also the simplest and cheapest. Intrinsic viscosity, which is measured from the flow time of a solution through a simple glass capillary, has considerable historical importance for establishing the very existence of polymer molecules. It also provides considerable physical insight. In this lab, each group will study the intrinsic viscosity of hydroxypropylcellulose, a common polymer derived from cellulose--hopefully at a different temperature. Viscosity in general For a discussion of viscosity, refer to the HowTo document on using the Wells-Brookfield cone and plate viscometer. The viscosity measured in a capillary viscometer is not obtained at a defined shear rate. Of several fixes to this problem, the simplest is simply to ignore it. This amounts to assuming that the fluid is Newtonian over the entire range of shear rates encountered by the fluid as it passes down the capillary. The Ubbelohde capillary viscometer The most useful kind of viscometer for determining intrinsic viscosity is the suspended level or Ubbelohde viscometer, sketched below: The viscometer is called suspended level because the liquid initially drawn into the small upper bulb is not connected to the reservoir as it flows down the capillary during measurement. The capillary is suspended above the reservoir. In conjunction with the pressure-equalization tube, this ensures that the only pressure difference between the top of the bulb and the bottom of the capillary is that due to the hydrostatic pressure--i.e., the weight of the liquid. Other designs, e.g., the Cannon-Fenske viscometer, do not provide for this, and will give erroneous results in an intrinsic viscosity determination. Such viscometers are useful in other experiments--e.g., checking the stability of some polymer solution, where one is only interested in measuring a change in the flow time. Use of the Ubbeloh

您可能关注的文档

文档评论(0)

guanjie8song + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档