压型钢板组合楼板

Diagonal shear strength Take one wave length (200 mm) as a checking unit, subjected to shear force as: V1 = V×200/1000 = 7.0 × 200/1000 = 1.4 kN f t = 1.10 N/mm2 (C20) 0.7 f t bbm h0 = 0.7×1.10×(70+50)/2×115 = 5.31 kN V1 Calculation of deflection Take one wave length (200 mm) as a checking unit. Elastic modulus of concrete: Ec = 2.55×104 N/mm2 aE = E s/E c = 2.06×105/2.55×104 = 8.08 Deflection under short term loading Equivalent width of concrete slab: Equivalent width of rib: second moment of area of the transformed section of one wave length of composite slab second moment of area per meter of slab: Isk = 5 Isk’ = 5×475×104 = 0.238 ×108 mm 4 pk = gk + qk = 2.954 +2 = 4.964 kN / m Deflection under long term loading Steel Deck P3623 3.7 Advanced composite floor systems a number of trends in modern construction have led to the development of more advanced forms of composite construction Fabricated beams with tapped webs Haunched beams Composite trusses Stub girders Parallel beam grillage system Beam with single web openings Beams with web openings Cellular and castellated beams Slim floor system 3.8 CONCLUDING SUMMARY The design of a composite slab must consider the performance of the profiled steel sheeting, when it acts as shuttering for the wet concrete during execution, as well as the composite performance of the steel and hardened concrete under the imposed floor loading. At the execution stage, the profiled steel sheeting acts as a thin-walled member. Its design must take into account the possibility of local buckling. The design of the composite slab must consider the resistance to positive and negative moments and also to vertical and longitudinal shear. The resistance to longitudinal shear at the steel/concrete interface is largely derived from embossments in the steel sheet or from connectors placed at the ends of the spans. Empirical methods are used to ensure adequate shear resistance. shallow floor systems, which

文档评论(0)

shenland + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档