Mitigation of Undesired Operation of Recloser Controls Due to对重合闸操作不便的缓解控制由于.pptVIP

Mitigation of Undesired Operation of Recloser Controls Due to对重合闸操作不便的缓解控制由于.ppt

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Mitigation of Undesired Operation of Recloser Controls Due to对重合闸操作不便的缓解控制由于

Inrush Current Second Harmonic One Method to Secure Relays Change Settings Change curve shape Raise pickup Raise time dial Testing Other Fast Curves Test Results Curve Trip 4 No R No N No 17 No 1 Yes A (TD = 2) Yes Disadvantages of Changing Settings Slows protection Is difficult to quantify distribution line inrush EMTP Real-time digital simulation A Better, Easier Solution: Second-Harmonic Blocking First Recloser Trip – Raw Event First Recloser Trip Harmonics Second Recloser Trip – Raw Event Second Recloser Trip Harmonics Second-Harmonic Blocking Logic First Event With Second-Harmonic Blocking Second Event With Second-Harmonic Blocking Substation Recloser Inrush Event Incorrect Second-Harmonic Blocking Step change in fundamental frequency Fourier transform Short-lived blocking (0.25 cycles) CT saturation Has low fault current and low X / R ratio Is backed up by slow curve CT Excitation Curve Path Forward Install three-phase 70 A reclosers with single-pole tripping Implement second-harmonic blocking on reclosers and feeder relays Perform coordination studies again Transformer Fuse Coordination Questions? Copyright ? MCEC and SEL 2014 Mitigation of Undesired Operation of Recloser Controls Due to Distribution Line Inrush Lee Ayers Mid-Carolina Electric Cooperative Larry Wright Schweitzer Engineering Laboratories, Inc. 53,000 active meters South Carolina counties Lexington Richland Newberry Saluda Aiken Mid-Carolina Electric Cooperative MCEC Discussion Reasoning for changing recloser style Experience with tripping due to inrush Factors affecting inrush Solutions to tripping during inrush Future plans to address feeder circuit coordination Example MCEC Distribution Circuit Hydraulic Recloser Clearing Curves Two Fast A and Two Slow B Curves Fast Curve Clears Temporary Faults Saves fuses Reduces outages Historical Data 90% of faults clear on fast curve 5% of faults clear on slow curve 5% of faults proceed to lockout Aging Recloser Fleet Reclosers were at least 20

文档评论(0)

118books + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档