Performance evaluation of an axially viewed horizontal inductively coupled plasma for optical emission spectrometry.pdfVIP
- 1、本文档共20页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Performance evaluation of an axially viewed horizontal inductively coupled plasma for optical emission spectrometry.pdf
?
ELSEVIER
Spectrochimica Acta Part B 50 (1995) 1207-1226
SPECTROCHIMICA ACTA PART B
Performance evaluation of an axially viewed horizontal inductively coupled plasma for optical emission spectrometry
Juan C. Ivaldla?*, Julian F. Tyson b
aThe Perkin-Elmer Corporation, 761 Main Avenue, Norwalk, CT 06859-0293, USA bDepartment of Chemistry, The University of Massachusetts, Box 34510, Lederle Graduate Research
Towers, Amherst, MA 01003-4510, USA
Received 18 January 1995; accepted 2 March 1995
Abstract A performance evaluation of a horizontal axially viewed inductively coupled plasma (ICP) for optical
emission spectrometry is presented. The main contribution of this work is the elucidation of the sources of analytical performance differences using practical diagnostics in the comparison of axial and conventional radial viewing of the ICP. Figures of merit such as detection limit, background equivalent concentration, precision, and dynamic range are compared for both viewing arrangements. The detection limit improvements.with axial viewing, known from previous work in the literature, are shown to be understood in the context of the signal-to-background-ratio relative-standard-deviation-of-the-background (SBRRSDB) theory. The usefulness of the SBR-RSDB approach as a diagnostic tool for understanding the detection limit improvement and identifying performance differences is demonstrated. This approach can be further utilized for quality control and quality assurance of instrument performance and detection limit results. Other characteristic differences between axial and radial viewing are presented including matrix effects on line signals and the magnitudes of spectral interferences from OH bands. An overall improvement factor of five in detection power was observed when using axial viewing compared with radial viewing. Keywords: ICP; ICP-OES; Optical emission spectrometry
1. Introduction
The detection limit advantages of the axially viewed inductively coupled plasma (ICP)
您可能关注的文档
- Multilayer diffusion in a composite medium with imperfect contact.pdf
- Multimarket contact and performance Evidence from emerging economies.pdf
- Multimodal learning for view-based 3D object classification.pdf
- Multiple views system to support awareness for cooperative design.pdf
- Multiscale characterization of head check initiation on rails under rolling contact fatigue Mechanical and microstructure analysis.pdf
- MUSIC-type imaging of perfectly conducting cracks in limited-view inverse scattering problems.pdf
- MVGS A new graph signature for self-reconfiguration planning of modular robots based on Multiple Views Theory.pdf
- MVPSys Toward practical multi-view based false alarm reduction system in network intrusion detection.pdf
- MVS A multi-view video synopsis framework.pdf
- Mycobacterium tuberculosis as viewed through a computer.pdf
最近下载
- 第一章 2.2 水量平衡.ppt
- 《GB/T 19326-2022锻制支管座》.pdf
- 2022年11月陕西省从优秀村社区干部中考试录用200名乡镇街道机关公务员上岸冲刺卷I含答案详解版(3套).docx VIP
- 2020年银行业从业人员职业操守和行为准则.pdf VIP
- 转预备党员思想汇报【银行】.pdf VIP
- 【新教材】人教版(2024)七年级上册英语Unit 4 My Favourite Subject教案.docx
- 米厂恒温仓库工程设计方案.docx
- 2024年党校入党积极分子培训考试必考重点知识汇编(共160题).doc VIP
- 《世界经典神话与传说故事》 测试题及答案.pdf
- 智能制造设备安装与调试职业技能等级标准(2021年).pdf
文档评论(0)