网站大量收购独家精品文档,联系QQ:2885784924

Manufacturers of blood between the two agents observed the results of cross-contamination.doc

Manufacturers of blood between the two agents observed the results of cross-contamination.doc

  1. 1、本文档共7页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Manufacturers of blood between the two agents observed the results of cross-contamination

 PAGE \* MERGEFORMAT 7 Manufacturers of blood between the two agents observed the results of cross-contamination Study: Lan Jian Ping Meng Yu Ming Cheng Hongge [Abstract] Objective: To observe the project between the two manufacturers of mixed lipid reagent cross-contamination arising from the situation in order to determine if the two manufacturers of lipid reagent can be mixed, as we choose the two manufacturers in the low-cost reagents without affecting the test results . Methods: A blood serum samples of four indicators, namely, TC (oxidase, TG (oxidase method, HDL-C (direct method, LDL-C (direct method to do 20 consecutive test, the first two manufacturers mixed with reagents to do, the purpose of observing the coefficient of variation, and then do the same serum of 20 consecutive separately reagents Branch, TC, TG and continuous two projects to do 20 other manufacturers of reagents HDL-C, LDL-C two projects, the purpose of observing the coefficient of variation. Results: four projects at the same time doing, the Branch, the TG results of poor reproducibility, was subject to interference, the two manufacturers of the items separately doing, the purpose of reproducibility was good. Conclusion: The two manufacturers of the blood can not mix reagents, the project can only choose one of four manufacturers of the reagents, or cross-contamination may have affected test results. [Keywords:] lipids, repeatability, cross-contamination Abstract Objectives: To evaluate the cross contamination results when different reagents from two factories were utilized jointly for blood-lipid test so as to determine the applicability of the joint utilization method and it may potentially help to reduce the cost of clinical test through selective usage of cheaper reagents of the two factories. Methods: One serum sample was tested 20 times for TC (with oxidase), TG (with oxidase), HDL-C (direct method) and LDL-C (direct method) through joint usage of reagents from bot

文档评论(0)

jiupshaieuk12 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6212135231000003

1亿VIP精品文档

相关文档