网站大量收购独家精品文档,联系QQ:2885784924

Myopia after LASIK refractive objective evaluation of.doc

  1. 1、本文档共19页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Myopia after LASIK refractive objective evaluation of

 PAGE \* MERGEFORMAT 19 Myopia after LASIK refractive objective evaluation of Author: Zhou Wei, Zheng Rui Zheng Jie Huang Rui Peng-chun 【Abstract】 Objective: To attempt to find a simple, accurate and not subject to regulation to determine the impact of refractive status means to support patients after LASIK vision acuity chart. Methods: Retrospective analysis of 400 received information on LASIK surgery in myopia. Preoperative refractive errors in accordance with the equivalent mirror-degree divided into 4 groups (≤-3.00D, ≤-6.00D, ≤-9.00D, ≤-12.00D). In accordance with corneal optical zone diameter and divided into 4 groups (5.5,6.0,6.5,7.0 mm). Corneal refractive respectively, all refractive errors degree and method of evaluation of three kinds of corneal topography. Results: The degree of-6.00D refractive errors and optical zone diameter of 6.5mm following more than three methods of the value of the expected value and the measured coincidence rate of 80% ~ 95%. All refractive errors-degree detection value of the expected value and the measured coincidence rate low, the difference was significant (χ 2 test, P lt;0.05). Degree-9.00D refractive error above and optical zone diameter of 6.0mm the following three methods of the value of the expected value and the measured coincidence rate of 70% ~ 80% difference between the groups was no significant (χ 2 test, Pgt; 0.05). Conclusion: LASIK surgery,-6.00D of myopia with corneal diopter below the expected value of evaluation is simple and reliable,-9.00D of myopia can be used below the expected value of evaluation of corneal topography BFS, computer Refractometer degree of refractive errors obtained by the conditioning effects, some more eye deviation. Keywords: myopia LASIK refractive topographic map Objective evaluation of refractive power after LASIK for myopia Abstract AIM: To find out a simple and exact method estimating refraction without interference by accommodation, so as to

文档评论(0)

jiupshaieuk12 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6212135231000003

1亿VIP精品文档

相关文档