Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing英文文献资料.docVIP

Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing英文文献资料.doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing英文文献资料

J. Biomedical Science and Engineering, 2011, 4, 235-241 JBiSE doi:10.4236/jbise.2011.44032 Published Online April 2011 (http://www.SciRP.org/journal/jbise/). Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing Brennen L. Lucas , Alexander C. M. Chong , Bruce R. Buhr , 1 1,2 1 1,2 Teresa L. Jones 1 , Paul H. Wooley 1 2 Department of Surgery, Section of Orthopaedics, The University of Kansas School of Medicine, Wichita, Kansas, USA; Orthopaedic Research Institute, Wichita, Kansas, USA. Email: alexander.chong@ Received 23 February 2011; revised 1 March 2011; accepted 3 March 2011. ABSTRACT cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva- tion of soft tissue and rigid stabilization are needed. Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to- lateral and one oblique, (II) two medial-to-lateral, (III) one medial-to-lateral and one anterior-to-po- sterior, and (IV) one medial-to-lateral, one ante- rior-to-posterior and one oblique in simulated distal metaphyseal fracture tibiae. Twenty-four Synthes EXPERT tibial IM nails were used for six speci- mens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm interlock- ing screws into simulated distal tibiae