Vo1.37 No.3 工业妒 第 37 卷第 3 期 Industrial Fumace May 2015 2015 年 5 月 余热锅炉低温过热器变形原因分析 纪东生,王方 (夭津市特种设备监督检验技术研究院,天津 3∞192) 摘 要:余热锅炉的低温换热器在使用过程中出现变形,影响了运行安全,需要定期更换变形的过热器管,造成经济 上的损失。针对锅炉运行、锅炉水位、过热器管壁温度分析变形原因,制定措施,从根本上解决了这一问题。 关键词:余热锅炉;低温;过热器;变形 文章编号:1∞1-6988(2015)03-∞41-04 中图分类号:TK229.929;TK223.3空 文献标识码:B Analysis of Deformation Reason of Low Temperature Heat Exchanger in Waste Heat Boiler JI Dongsheng, WANG Fang m叫iin Special Equipment lnspection lnstitute, Tianjin 300192, China) Abstract: 币le low temperature heat exchanger of waste heat boiler deforms during applying, which affects the security of operation. It also results to economic damage since super-heater need regular replacement. Aiming at boiler operation, water level of boiler and temperature of the pipe wall of super- heater, the reasons of the deformation are analyzed and the measures 缸e taken in order to get the fundamental solution of the problem. Key words: waste heat boiler; low temperature; super-heater; deformation 某公司运行的一台用于发电的余热锅炉,每次 1 锅炉运行过程分析 启炉运行一年后都会在部分高温以及低温过热器 1.1 启炉过程分析 管处发生变形现象,变形挠度一般为60-120 mm。严 公司曾多次组织专家进行研究,并先后两次对 重影响了运行安全,并造成经济上的损失。 本文通过分析锅炉起炉、运行过程、运行中锅 高、低温过热器结构和启炉方式进行改进,以期达 炉水位状况、锅炉过热器管管壁温升清况、过热器 到缓解高温过热器变形的目的。更改过热器结构的 管管样等因素,研究低温过热器变形原因[叶。 主要措施是将先前的4排高温过热器管和8排低温 该余热锅炉入口余热烟气温度990 C,烟气流