给水泵再循环系统介绍(国外英语资料)
给水泵再循环系统介绍
Introduction of pump recirculation system
I. overview
In thermal power plants, the process of doing work depends on the circulation of water (that is, water is pumped from the feed pump to the boiler, in the pot)
The steam is heated in the furnace and the steam expands in the gas turbine. After the work is done, the steam is condensed into water by the condenser, and thus circulates
Reciprocating Realized. During the entire cycle, the safe operation of the water pump is achieved by this cycle
Key.
The amount of water supplied to the water pump varies with the load of the boiler. Feed water pump at start-up or at very low load
It is very likely that the water will run under the condition that the water supply is small or the water supply is zero, and the water will suffer the friction of the impeller for a long time in the pump
Heating, and make the water temperature rise, the water temperature rose to a certain extent, will occur vaporization, forming cavitation. Cause to
Water pump damage. In order to prevent the occurrence of the above phenomenon, the water pump is exported to the deaerator (or condenser) water tank
A recirculating system shall be installed between the water pump and the water pump. When the feed water is just started or the water supply is small to a certain extent, it can be opened and recycled
Ring system. Return a part of the water to the deaerator tank to ensure a certain amount of water (generally about the rated flow)
(30%) through the pump, without causing the pump to rise in water temperature and evaporation. When the water supply is under normal conditions
The recirculation system is closed.
The recirculation system consists of a minimum flow valve, a check valve, and a flow measuring system.
In the system, the flow measurement system determines when the recirculation system is switched on or off;
The purpose of the check valve is to allow only the pump to pump water outside, but not the water reverse flow return pump. Water p