- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
网孔支架辅助微弹簧圈治疗已破裂颅内动脉瘤的临床-第三军医大学学报
网孔支架辅助微弹簧圈治疗已破裂颅内动脉瘤的临床疗效分析
赖挺,刘俊*,杨辉,周政,李正杨(400037重庆,第三军医大学新桥医院神经外科)
[摘要] 目的 探讨网孔支架辅助微弹簧圈在已破裂颅内动脉瘤栓塞治疗过程中的操控性,相关并发症及临床疗效。方法 回顾性分析应用网孔支架辅助微弹簧圈栓塞治疗60例已破裂颅内动脉瘤患者资料。结果 所有60枚支架顺利释放到位。术后即刻造影,动脉瘤获100%栓塞34个,95.0%栓塞11个,90.0%栓塞14个,80.0%栓塞1个。术中出现血管痉挛4例,动脉瘤破例3例,血栓形成1例。术后随访3~18个月,死亡2例,患者术后生存质量与术前Hunt-Hess分级之间有统计学差异(P〈0.05)。患者术后获影像学随访23例,其中DSA随访19例,1例出现支架内血管狭窄,均无动脉瘤复发。结论 使用网孔支架辅助微弹簧圈栓塞治疗已破裂颅内动脉瘤过程中,操作性良好,安全性高,疗效满意,术者娴熟的技术,对手术时机准确的把握和对介入材料正确的选择有助于减少相关并发症的发生。
[关键词] 破例颅内动脉瘤;网孔支架;微弹簧圈;血管内治疗
Clinical study on mesh stent-assisted micro-coil for treating ruptured intracranial aneurysms
Lai Ting,Liu Jun,Yang Hui,Zhou Zheng,Li Zheng Yang(Department of Neurosurgery,Xingqiao hospital,Third Military Medical University,Chongqing 400037,China)
[Abstract] Objective To explore the handling,complications and clinical efficacy of mesh stent-assisted micro-coil for treating ruptured intracranial aneurysms.Methods The clinical data of 60 patients with mesh stent-assisted micro-coil for treating ruptured intracranial
aeurysms was analyzed.Results All 60 stents were successfully released in place. The aneurysm was 100% embolism in 34 cases, 95% embolism in 11 cases, 90% embolism in 14 cases, 80% embolism in 1 case.The complications of surgery included the Vasospasm in 4 patients , the rupture of aneurysms in 3 patients and the thrombosis in 1 patient. The all patients had been followed up for 3-18 months after surgery,and 2 of them had been died,. There were significant differences between in the patients quality of life. Between the groups of preoperative Hunt-Hess grade.The patients received postoperative imaging follow-up of 23 cases, including DSA follow-up of 19 cases. In addition to the one case appeared stent vascular stenosis and no aneurysm recurrence.Conclusion It is satisfied using mesh stent-assisted micro-coil for treating ruptured intracranial aneurysms. The stent has good compliance,therefore it can be delivered and deployed easily and positioned precisely with hi
您可能关注的文档
最近下载
- 政论型电视专题政论片.ppt VIP
- 新版GCP临床试验伦理规范培训考试题一套 .pdf VIP
- 新编高等数学(理工类)第一章 极限与连续.ppt VIP
- 13J104 蒸压加气混凝土砌块、板材构造(OCR).pdf VIP
- 2024版思想道德与法治专题1担当复兴大任成就时代新人.pptx VIP
- 章绍同《鼓浪屿狂想曲》.pdf VIP
- UG机械设计实例教程 第2章 曲柄滑块机构建模与运动仿真.ppt VIP
- 2025年最新人教版小学二年级数学上册教学计划及进度表(新课标,新教材).docx
- 2024-2025学年小学道德与法治统编版(2024)三年级上册教学设计合集.docx
- 河道整治及生态修复工程监理细则(88页)_最新版.pdf VIP
文档评论(0)