配电高级(Distribution of senior).docVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
配电高级(Distribution of senior)

配电高级(Distribution of senior) choose 1. The period of Chinas labor frequency alternating current is 0.02 s. 2. Ohms law is the relationship between voltage, current and resistance in a given positive direction. 3. Ac motor and transformer are used to make iron core materials for the purpose of reducing eddy current and magnetic hysteresis consumption. 4. The rule for determining the direction of the carrying conductor in the magnetic field is the left hand rule. 5. The law used to determine the direction of induced electromotive force induced by wire cutting in magnetic field is the right hand rule. 6. The insulation resistance should not be less than 1000 megaohm when tested in the 10kv metal oxide arrester. 7, 1 kv and the following power distribution devices shall be tested with voltage of 1 kv. The insulation resistance of the transmission circuit is above 10 megaohm, and it can be replaced by the 2500 volt insulation resistance meter. 8. The voltage standard of ac voltage withstand test is 28 kv when the power transformer of 10kv oil is used for the handover test. 9. The distance between the vertical grounding body of the grounding device should not be less than double the length. 10. The minimum size of the ground wire embedded in the buried soil of the round steel is 10mm in diameter. 11. The independent lightning rod should not be located in the place where the person is often traveling. The distance between the lightning rod and the grounding device and the road or the entrance should not be less than 3 meters. 12, isolating switch conductive contact part of the good or bad, 0.05 mm x 10 mm feeler check are available, and the width of contact area is 50 mm and below, its into depth should not be more than 4 mm. The rated current of the secondary fuse of transformer is selected by the secondary rated current of the transformer. 14. The voltage range of PVC plastic cable is 1 to 10 kv. The breakdown of the line insulator occurs inside the insulator. 16, 10 kv

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档