2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena
Identification of Incipient Discharges in Gas Insulated System using
Acoustic Emission Technique
R. Sarathi, Vishal Dubey and Y.G. Sriivasat
Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai-600 036, India.
tDepartment of Mechanical Engineering, Indian Institute ofTechnology Madras, Chennai-600 036, India.
Abstract: The reliability of the SF6 gas filled GIS is GIS is scanty. Having known all this, in the present
adversely affected by the presence of foreign particles in work, a methodical experimental study was formulated
the insulation structure, which initiates partial to understand the partial discharge activity under
discharges leading to catastrophic failure of insulation composite voltage formed by AC and DC voltages, in
structure. The literature on partial discharge activity GIS using Acoustic Emission (AE)technique.
study under the composite voltages in GIS is scanty.
Having known all this, in the present work, a Experimental
methodical experimental study was formulated to
understand the partial discharge activity under The experimental setup used for the measurement of
composite voltage formed by AC and DC voltages, in acoustic signal generated due to partial discharges in the
GIS using Acoustic Emission (AE) technique. The gas insulated system, under the composite voltage
Acoustic emission signal parameters Viz. amplitude, formed by AC and DC voltages is shown in Fig. 1.
rise time of the pulse, duration of the AE signal, counts
and the energy content of the AE signal were analysed (i) Test Apparatus
and the characteristics of discharges under different
voltage profiles were explained.
您可能关注的文档
- 大论文28.Airborne LiDAR acquisition, post-processing and accuracy-checking for a 3D WebGIS of Copan, Honduras.pdf
- 大论文29.Automatic extraction of highway light poles and towers from mobile LiDAR data.pdf
- 大论文30.Automatic classification of urban pavements using mobile LiDAR data and roughness descriptors.pdf
- 大论文31.An investigation of DEM generation process based on LiDAR data filtering,decimation, and interpolation methods for an urban area.pdf
- 大论文32.LiDAR based prediction of forest biomass using hierarchical models with spatially varying coefficients.pdf
- 大论文33.Using LiDAR to characterize logjams in lowland rivers.pdf
- 大论文34.An efficient approach to 3D single tree-crown delineation in LiDAR data.pdf
- 大论文35.Effective LiDAR-based modelling and visualisation of managed retreat scenarios for coastal planning:An example from the southern UK.pdf
- 大论文LiDAR:An important tool for next-generation phenotyping technology of high potential for plant phenomics国内的.pdf
- 大论文Matching 3D face scans using interest points and local histogram descriptors.pdf
- 电路引用Influence of aged conductor surface conditions on AC corona-generated audible noise with a corona cage.pdf
- 电路引用Measurement of audible noise from transmission lines.pdf
- 电路引用On-line monitoring of insulator contamination causing flashover based on acoustic emission.pdf
- 电路引用Partial discharge classification using learing vector quantization network model.pdf
- 电路引用Partial discharge classification using principal component analysis combined with self-organizing map.pdf
- 电路引用partial discharge detection for GIS a comparison between UHF and acoustic methods.pdf
- 电路引用Partial discharge detection in gas insulation load breaker switch.pdf
- 电路引用Partial discharge diagnosis of gas insulated station(GIS) using acoustic method.pdf
- 电路引用Partial discharge in gas insulated substations(GIS) a development and engineering perspective.pdf
- 电路引用Partial discharge part XIV acoustic partial discharge detection-practical application.pdf
文档评论(0)