安萨尔多故障#(Anzaldo # fault)

安萨尔多故障#(Anzaldo # fault) Anzaldo fault diagnosis 1.1 P - O (missing item) Line voltage loss protection interrupts, protection is accomplished by voltage monitoring hardware circuits (P15, N15, and P5). An interrupt occurs when the value of P5 is higher than 5.25V or less than 4.75V, resulting in a reset of the converter. Fault: terminal XM2-U, V, W terminal voltage drop. Check: check the supply voltage and synchronous voltage. Measures: reclosing. Fault: power failure. The power supply voltage is over limit, the monitoring end is P5-TP5, P15-TP6, N15-TP7, OV reference point is P8, terminal threshold is P5 + 5%, P15 and N15 + 20%. Measures: the power supply voltage exceeds the limit, and replace the P power board. Fault: C control panel fault. Check: the supply voltage is within the limit. Monitoring end P5 - TP5, P15 - TP6, N15 - TP7; OV reference point is P8, terminal threshold: P5 + 5%, P15 and N15 + 20%. Measure: replace the C power panel. 1.2 P - -1 (external protection) External protection interrupt. Fault: the terminal XM-20 logic signal is missing (+24V). Check: measure terminal XM1 - 20,22 voltage, determine its value is +24V + 4V. Through the Hardware Status function (Par.2.2.6), the Logic Input reads the logical input M20 Ext_P state value OFF. If the terminal voltage is zero, the logic input status is ON and the protection action is performed. Measures: the terminal XM1-20 logic signal is re enabled, and the voltage of the terminal XM1-20 22 is measured to be +24V + 4V. Fault: C control panel fault. Measure the voltage of terminal XM1-20,22 and determine its value +24V + 4V. Through the Hardware Status function (Par.2.2.6), the Logic Input reads the logical input M20 Ext_P state value ON. Measure: replace the C control panel. 1.3 P - 2 (maximum current) The maximum current protection interruption is protected by a hardware circuit that connects the CT load resistor (Par.3.3). Fault: the current loop is unstable or slow. Check: check the response of the cu

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档