网站大量收购独家精品文档,联系QQ:2885784924

室内空气中二氧化碳的测定方法(Method of determination of carbon dioxide in indoor air).doc

室内空气中二氧化碳的测定方法(Method of determination of carbon dioxide in indoor air).doc

  1. 1、本文档共15页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
室内空气中二氧化碳的测定方法(Method of determination of carbon dioxide in indoor air) Method of determination of carbon dioxide in indoor air The methods of determination of carbon dioxide in air mainly include non-disperse infrared gas analysis, gas chromatography, volumetric titration and so on. E. 1 nondispersive infrared gas analysis E. 1.1 relevant standards and basis The method is mainly based on GB/T18204.24 method of determination of carbon dioxide in public places. E. 1.2 principle Carbon dioxide has a selective absorption of infrared ray. In a certain range, the absorption value is linear with the concentration of carbon dioxide. The concentration of the sample carbon dioxide is determined according to the absorption value. E. 1.3 measurement range 0 ~ 0.5%; Between 0 and 1.5 %. The minimum detectable concentration was 0.01%. E. 1.4 reagents and materials E. 1.4.1 color silica gel: dry 2 h under 120 ℃; E. 1.4.2 non-aqueous calcium chloride: analytical pure; E. 1.4.3 high purity nitrogen: 99.99% purity; E. 1.4.4 caustic asbestos: analytical pure; E. 1.4.5 plastic aluminum foil composite film mining bag 0.5l or 1.0l; E. 1.4.6 co2 standard gas (0.5%) : stored in aluminum alloy cylinders. E. 1.5 instruments and equipment Carbon dioxide nondispersive infrared gas analyzer. The main performance indexes of the instrument are as follows: Measurement range: 0 ~ 0.5%; Two 0 ~ 1.5%; Reproducibility: less than or less than 1% full scale; Zero drift: no more than or minus 3% full scale / 4h; Span drift: no more than or minus 3% full scale / 4h; Additional temperature error: + / - 2% of full scale / 10 ℃ or less (10 ℃ ~ 80 ℃); Carbon monoxide interference: 1000mL/m3 CO. Additional error: 220V plus or minus 10% is equal to or minus 2% full scale. Starting time: 30min; Response time: the pointer indicates the full scale of 90% of the time 15s. E. 1.6 sampling Using plastic aluminum foil compound film to collect air bags, extract the air flush 3 ~ 4 times, gas extraction 0.5 L or 1.0 L

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档