超高层建筑给排水及消防设计体会(Experience of water supply and drainage and fire protection design of high-rise building).docVIP

超高层建筑给排水及消防设计体会(Experience of water supply and drainage and fire protection design of high-rise building).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
超高层建筑给排水及消防设计体会(Experience of water supply and drainage and fire protection design of high-rise building)

超高层建筑给排水及消防设计体会(Experience of water supply and drainage and fire protection design of high-rise building) Water supply and drainage and fire protection design of super high-rise building Guangzhou power dispatching building is a comprehensive building which integrates office, production, scientific research and conference functions. The main building is 36 floors, stone into 7 layers, the top is 4 layer microwave antenna tower, a total construction area of about 5 * 104m2, introduces the design of water supply and drainage and fire water supply system of the construction of the building height of 136.00m. in this paper, and put forward some design ideas. 1. Water supply 1.1 water sources from Tianhe south two road tap water pipe, DN200mm water inlet pipe, the introduction of the 3 underground pool, the pool volume of about 500m3, divided into two spaces (life, fire fighting). 1.2 domestic water supply system Calculation of water consumption Vertical district water supply mode. Consider the use of hydrostatic pressure of no more than 0.35MPa, so vertical pressure reducing valve is divided into four zones, 24 sets of intermediate water transfer tank. Zone 1: basement to ground 3 floor, municipal water pressure direct water supply. 2 areas: 4 to 13 layers, from 24 layers of water tank after decompression valve to supply. 3 areas: 14 to 21 layers, provided by 24 layers of water tank. Zone 4: 22 to 36, supplied by weather pool. 1.3 fire hydrant water supply system for the building fire risk category as a class a public building, high-rise building height exceeds 100m, the fire hydrant water supply system according to the water pressure is divided into upper, middle and lower three areas, outdoor fire hydrant water 30L/s, indoor water hydrant 40L/s. fire duration is considered as 3h, three layer underground life fire water tank used storage 3H indoor water hydrant and 1H spray water. The middle and lower areas are basement, and the negative is 3 to 23. The pressurized wat

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档