- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
dyn变压器的特点(The characteristics of dyn transformer)
dyn变压器的特点(The characteristics of dyn transformer)
There are three kinds of connection method of transformer three-phase winding, star connection, triangle connection and zigzag connection. In the winding connection used in capital letters A, B, C high voltage winding end, with X, Y Z, said at the end; use lowercase letters a, B, C low voltage winding head end, x, y, Z said at the end, O neutral point.
The new standard is connected by star, triangle and zigzag. The high voltage windings are represented by symbols Y, D and Z, respectively. The middle and low voltage windings are represented by Y, D and Z respectively. When the neutral points are extracted, they are represented by YN, ZN and YN, Zn, respectively. One of the two windings of the common transformer having a nominal voltage below the nominal voltage is indicated by the symbol a. Transformer in accordance with the order of high voltage, medium voltage and low-voltage winding combination, that is, winding connection group. For example, the high voltage is Y and the low voltage is the yn connection, then the winding connection group is Yyn. In addition, the clock method indicates that the relationship between the high and low pressure side links is the join group.
The three commonly used groups have different characteristics:
1 Y connection: the winding current is equal to the line current, winding voltage is equal to the line voltage of 1/ V 3, and can be made into graded insulation; in addition, the neutral point can lead to ground, and can also be used to realize the four wire power supply. The main drawback of this connection is the absence of three harmonic currents in the loop.
2 D join: the characteristics of the D join are the opposite of the characteristics of the Y connection.
3 Z connection: the Z connection has the advantage of the Y connection. The number of turns is 15.5% more than the Y. Relatively large cost.
According to GB/T6451-1999 three phase oil immersed power transformer technical param
您可能关注的文档
- 39综合测试题(39 comprehensive test questions).doc
- 3d max札记(3D max札记).doc
- 3dsmax的模型优化技巧默(3dsmax model optimization techniques silently).doc
- 3dmax布光的心得(3DMAX lighting experience).doc
- 3d_max中材质(Material in 3d_max).doc
- 3d左右格式(About 3D format).doc
- 3d术语(3D terminology).doc
- 33建筑构造与详图(33 building construction and detailing).doc
- 3d电影简介(3D movie profiles).doc
- 3d立体影片格式介绍(Introduction of 3D stereoscopic film format).doc
- e5筑底部商业用房消防设计常见问题探讨(E5 built on common problems in the design of fire at the bottom of commercial housing).doc
- ebs多节点克隆(EBS multi node cloning).doc
- elisa测定错误结果的原因分析(Analysis of the causes of erroneous results for the determination of ELISA).doc
- emule优化(电驴优化).doc
- en清明节由来(EN Tomb-sweeping Day origin).doc
- epc模式下项目的质量控制(The quality control mode of EPC project).doc
- erp名称解释(Explain the ERP name).doc
- emiemc硬件设计实用技巧(The hardware design of emiemc practical skills).doc
- erp沙盘的由来(The origin of ERP sandbox).doc
- erp系统中物料的编码原则及方法档(File encoding principle and method of material in ERP system).doc
文档评论(0)