框架设计注意事项(Frame design notes)

框架设计注意事项(Frame design notes) The framework design of easily overlooked problems and Solutions (a) structural problem The 1. trench depth is greater than the depth of foundation, the foundation should be deepened; When a layer of filler wall thickened by ground bearing, trench should deepen or lintel; The fundamental beam in the range of 0, trench should deepen to avoid high beam. When the 2. layers high, should not use the way of filling wall thickening ground bearing, to prevent cracks caused by the deformation coordination, are advised to set up the fundamental beam, small deformation (when the opening is not in the side, due to the impact, columns and wing wall at this time is actually the wall beam model). When the span is large, the pull beam can be set to solve the deformation of cross column pier. The 3. wall filled with the main structure of the connection between how specific reference code for seismic design of the 13 chapter (non structural) or 02SG614 (frame structure filled with small hollow block wall structure). 4. review column minimum stirrup ratio, beam negative reinforcement into the side column, whether more than 0.4LaE on the frame beam torsion awning main reinforcement and stirrup ratio is more than enough 0.28ft/fy. 5. stair board upper reinforcement should lower ribs 0.5 ~ 0.67, and more than 200 people @ Phi 8, up and down the same reinforcement is not reasonable; the landing beam column should not be connected with the upper frame beam, are connected to form a small internal frame, frame beams with complex, small column tension and the column section, amounting to 300, should take the strength reduction coefficient of 0.8; the platform beam should match the negative reinforcement; main frame beam column for the presence of the extension of the length of the beam direction and the vertical direction of the torque calculation, not taking into account the structure should be reinforced and the stirrup. 6.: roof leakage load of rigid and flexib

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档