混凝土强度检测中回弹法检测有那些要注意的地方

混凝土强度检测中回弹法检测有那些要注意的地方 1, the current rebound method for technical specification for inspection of concrete strength by rebound method JGJ/t 23-2011, the concrete implementation method very detailed; 2, to determine whether the object is suitable for testing by rebound method; 3, through the resiliometer verification, and in the period, at the same time, each test should be carried out before the calibration, namely: the Rockwell hardness of HRC steel anvil was 60 + 2, rebound instrument calibration value should be 80 + 2; 4, when using the resiliometer environmental temperature should be -4~40 DEG c; 5, using the rebound method to test the strength of concrete structure or component should have the following information: A project name and design, construction and supervision (or supervision) and the name of the construction unit: B structure or component name, size, quantity and strength of concrete; C cement, strength, stability, factory name, sand and stone varieties, grain size, admixture or admixture of varieties, volume and mix ratio etc.; D template type, concrete pouring and curing, and molding date; E test. 6, according to the actual situation, combined with the specification to determine springback parts or components; 7, according to the component detection test, test area of each structure or component shall comply with the following provisions: A a structure or component test area number should not be less than 10; B to a direction of size less than 4.5m and the other direction component size is less than 0.3m, the number of the test area can be reduced appropriately, but should not be less than 6; The two adjacent areas of the spacing of C should be controlled within 2m; D test area from the end components or construction joint edge distance should not be greater than 0.5m, and should not be less than 0.2m; E survey area should not be larger than 0.04m2, and should be evenly distributed; F in the important parts of components and the weak parts must h

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档