- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
电机拖动试题(变压器)(Motor drive test questions (transformers))
电机拖动试题(变压器)(Motor drive test questions (transformers))
In order to get 93 sinusoidal EMF, when the core is not saturated, the no-load current waveform into what? Why? 9-4, the concept of magnetic potential balance and its role in the analysis of transformers are described. 9-5, why can the no-load loss of transformers be approximately regarded as iron consumption, while the short-circuit loss is regarded as copper consumption? Are there actual differences between the actual iron consumption and copper consumption as well as the no-load loss and the short-circuit loss when the transformer is in actual load? Why? 9-6, the other conditions of the transformer remain unchanged, only the original and vice side coil turns change + 10%, how about the influence of 1 sigma and M? What if the voltage applied outside is only changed by + 10%? What if the frequency is only changed by + 10%? 98 a transformer, the original design frequency is 50 Hz, it will now receive a 60 Hz power grid operation, rated voltage constant. What is the impact on the exciting current, iron, leakage reactance, voltage change rate? 9-13 will be a 1000 turns of the core coil to 110 volts, 50 Hz AC power, read from the ammeter reading, 1 = 0.5 A, 1 = 10 W, the core after pumping, current and power 100A and 10kw. Assuming no leakage, try: (1) the parameters in the two cases, the equivalent circuit and vector diagram (with the same size painting), (2) magnetizing current and iron consumption current; (3) the same maximum in two cases.
X
X
I
P
U = 6000230 = 100 KVA, the former side rated voltage U 9-14 has a single phase transformer, rated capacity S f = 50 hz. The resistance and leakage reactance of the former coil are r = 4.32 ohm, r = 0.0063, X sigma = 8.9, volt, X sigma = 0.013?. Calculate: (1) converted to r high voltage side short circuit resistance, short circuit reactance and impedance of X Z; (2) converted to R low voltage side short circuit resistance, short circuit reactance and impedance of X Z;
您可能关注的文档
- 注资萨博 华泰冲击北汽(Inject Saab, Huatai impact Beiqi).doc
- 泰和高层住宅钢结构设计及经济指标分析(Steel structure design and economic index analysis of Taihe high rise residential building).doc
- 泵 供水设备(Pump water supply equipment).doc
- 泵站技术改造规程条文说明(Technical regulations for technical renovation of pumping station).doc
- 泵站总结(Pumping station summary).doc
- 注册设备工程师基础考试大纲(Registered equipment engineer basic test outline).doc
- 泵送混凝土施工方法(Pumping concrete construction method).doc
- 洁净室沉降菌测试标准操作规程(Standard Practice for test of settling bacteria in clean rooms).doc
- 洋区号(Area code).doc
- 泵与压缩机试题b(Pump and compressor test questions B).doc
- 电气技师论文(Electrician's thesis).doc
- 电气石的起源与特点(The origin and characteristics of tourmaline).doc
- 电气符号中英文(Electrical symbols in Chinese and English).doc
- 电气系统工程小结(Brief summary of electrical system engineering).doc
- 电气试题4(Electrical questions 4).doc
- 电气规范浅谈(Discussion on electrical specifications).doc
- 电气通用设备(Electrical general equipment).doc
- 电流互感器在变电运行中的应用_中国高新技术企业_zcom_com杂志门户(The current transformer used in _ substation operation in Chinese high-tech enterprise _zcom_com journal portal).doc
- 电流信号与电压信号的讨论(Discussion of current and voltage signals).doc
- 电涡流(eddy current).doc
文档评论(0)