结构相关说明(Structure specification).docVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
结构相关说明(Structure specification)

结构相关说明(Structure specification) The structure of professional uniform technical measures of a project (electrical part) A, general information 1, structure: Shear wall structure (top) Frame structure (pure basement, commercial, kindergarten) Shear wall (including individual short limb shear wall), seismic grade: Three 2, the structure of irregular rules: 3, design earthquake group: group second, II site, Tg=0.40s 4, the seismic fortification intensity of 7 degrees, the acceleration of 0.10g 5, the cycle reduction coefficient: 0.85 (18), 0.9 (26), 6, calculate the number of modes: The top 15 or 18 (usually adjust the computer when 9 or 12 desirable to save time, construction plans with 15 or 18) Business 6 9 kindergarten 7, considering the accidental eccentricity and bidirectional earthquake (according to the procedures for greater value, were calculated with the specification does not conflict) Considering the coupling A diagonal member, still need additional horizontal seismic direction corresponding 8, the simulation of construction loading: 3 (usually adjustable electrical load available is 1 to save time, pay attention to the axial compression ratio by 3 loading control) 9, the beam stiffness reduction: 0.7, when a large number of beam reinforcement beams when super desirable 0.55~0.7, only a few relatively small cross high should separate review, should not be the total parameters of connection stiffness reduction coefficient is too small. The other note: both ends of the shear wall plane and span ratio is less than 5 of the beams beam, beams should intervene in the special non component information in. 10, wind load calculation, shape coefficient of 1.4, basic wind pressure: 0.3 (18 and below), 0.35 (26), the ground roughness category: B In 11, the stiffness amplification coefficient: 2 beam torque reduction coefficient: 0.4 12, only in the calculation of displacement, check the floor stiffness is infinite, the rest are not checked floor stiffness infinite. 13

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档