网站大量收购独家精品文档,联系QQ:2885784924

仪器分析(instrumental analysis).doc

  1. 1、本文档共16页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
仪器分析(instrumental analysis)

仪器分析(instrumental analysis) The second chapter gas chromatography analysis 1. when the following parameters change: (1) the column length is shortened; (2) the stationary phase changes; (3) the flow velocity of the mobile phase increases; (4) does the decrease in the partition coefficient result from the decrease in comparison; why? A: the change in the stationary phase causes a change in the partition coefficient because the partition coefficient is only related to the nature of the component and the nature of the stationary phase and the mobile phase Therefore, (1) shortening of column length will not result in change of distribution coefficient (2) the change of stationary phase results in the change of partition coefficient (3) increasing the velocity of the mobile phase will not cause the change of the distribution coefficient (4) a decrease in the distribution coefficient does not result in a decrease in comparison 2. when the following parameters change: (1) the column length increases; (2) the stationary phase volume increases; (3) the flow velocity decreases; (4) does it cause the change of the distribution ratio when compared with the increase; why? Answer: k=K/b, and b=VM/VS, the distribution ratio, in addition to the composition, the nature of the two-phase, column temperature, column pressure outside, and also compared with, and with the flow phase flow velocity, column length independent Reason: (1) not change, (2) increase, (3) do not change, (4) decrease 3. can the possibility of separation be judged according to the number of theoretical plates? Why? Answer: No, the effective plate number only indicates the column efficiency and the column separation capability, while the possibility of separation depends on the difference of the partition coefficient between the stationary phase and the mobile phase 4. in a 2 m long column, a mixture of analysis, get the following data: the retention time of benzene, toluene, ethylbenzene and were 1 20 , 2 and 2 3

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档