comparison of the five different methods in arterial diameter measurement比较五种不同的方法在动脉直径测量.pdfVIP

comparison of the five different methods in arterial diameter measurement比较五种不同的方法在动脉直径测量.pdf

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
comparison of the five different methods in arterial diameter measurement比较五种不同的方法在动脉直径测量

Surgical Science, 2011, 2, 204-208 doi:10.4236/ss.2011.24045 Published Online June 2011 (http://www.SciRP.org/journal/ss) Comparison of the Five Different Methods in Arterial Diameter Measurement 1 1 2 2 2 Orhan Babuccu , Bulent Tekerekoglu , Huseyin Ozdemir , Halit Besir , Sadi Gundogdu 1Zonguldak Karaelmas University, Faculty of Medicine, Department of Plastic, Reconstructive and Aesthetic Surgery, Zonguldak, Turkey 2Zonguldak Karaelmas University, Faculty of Medicine, Department of Radiology, Zonguldak, Turkey E-mail : orhanbabuccu@.tr Received January 21, 2011; revised May 6, 2011; accepted May 16, 2011. Abstract Background/Aims: In this study, the different types of arterial diameter measurement methods were com- pared with each other on rat model. Methods: The study was planned in three phases. In phase 1, all subjects (n = 30) underwent high resolution B-mode ultrasound examination and external diameter of the right com- mon carotid artery (RCCA) was measured. In phase 2, RCCA was explored. In phase 3, rats were put into three groups. Group 1 was kept at –20˚C, group 2 was embedded in 4% formaldehyde solution. In group 3, circulatory system was filled with %20 latex solution. In all groups, digital image of the RCCA was taken after the processes mentioned above. Images were assessed by Image—Pro Plus software. Results: The greatest average diameter was observed in the high resolution B-mode ultrasound (phase 1). In group 1 and 2, direct measurement of the RCCA on living animal (phase 2) gave significantly wider diamet

您可能关注的文档

文档评论(0)

xyz118 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档