Annex Manufacturer maintenance for stationery machines to 1.1 Cable chain Open chain and check for cable twisting Christian Disselkamp Seite 1 08.03.2006 T:\9888\540030\Doku to Manufacturer maintenance ENU.doc Annex Manufacturer maintenance for stationery machines to 1.3 Central oiling Unit The Central oiling Unit Is used to provide lubrication to the toothed rack Featurest Values Receptacle capacity 1,5 Liter Period of greasing 25 min. impulses Duration of greasing 30 sec. impulses Lubricants Flow fat WEEKE-part no.: 4-017-02-0040 T:\\9883\\511230\\X0001tb.jpg Christian Disselkamp Seite 2 08.03.2006 T:\9888\540030\Doku to Manufacturer maintenance ENU.doc Annex Manufacturer maintenance for stationery machines Level of the lubricant dispenser Check once a week the level of the lubricant receptacle 14.4 of the central greasing for the toothed racks of the X- and Y- axis. • Make sure that the level does not fall below the minimal level 14.3! • Unscrew manually the lubricant receptacle 14.4. • Fill-up oil • Screw-on the lubricant receptacle Attention: While filling-up make sure that everything is absolutely clean! Only use the indicated oil sort T:\\9883\\511230\\X0001tb.jpg 14.3 14.4 Only use clean oil, Scratch . Christian Disselkamp Seite 3