发电机反事故技术措施(Technical measures for generator anti accident).docVIP

发电机反事故技术措施(Technical measures for generator anti accident).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
发电机反事故技术措施(Technical measures for generator anti accident)

发电机反事故技术措施(Technical measures for generator anti accident) According to incomplete statistics, from 1978 to 1981 during the four years of generator accident, the country and more than 6000 kilowatts generator damage for 177 times, the average annual accident rate for 2.7 times / 100, than between 1975 and 1977 the accident rate dropped 1.23 times / 100. Cause of the accident rate, is the main units to seriously implement the technical measures against accidents of the generator operating procedures and set in 1979, aiming at the existing problems of large turbo generator, a large-scale transformation and processing. The main categories of accidents in recent years are: coil insulation breakdown, short circuit, core burn, water cooler, water and other Water Leakage. The meeting according to the above, on 1979 the anti accident technical measures a slight modifications and additions are sent for each unit to carry out. It should be pointed out that in recent years due to the fault of excitation system of generator shutdown caused many accidents, should pay attention to, to take measures to improve the excitation system. The accident of excitation system and anti accident measures will be sent. A, prevent the breakdown of insulation of generator stator Unit 1. acceptance and maintenance, should carefully check whether the matter is due to stator slot wedge, end ring and block is tied with the coil tie pad tightly, mechanical fasteners are tight lock, loose wear phenomenon, especially yellow insulating unit, more attention should be paid to. If found problems should be treated in a timely manner. The new machine is put into operation for 5000 to 8000 hours, should be out of the rotor, to conduct a comprehensive inspection of the unit. Check and reinforcement of the unit, should continue to strengthen the monitoring, through the unit overhaul should be detailed review, to prevent recurrence of insulation wear phenomenon. 2. for the old, many due to insulation insulation

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档