ab模块灯故障处理(Troubleshooting of AB module light).docVIP

ab模块灯故障处理(Troubleshooting of AB module light).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
ab模块灯故障处理(Troubleshooting of AB module light)

ab模块灯故障处理(Troubleshooting of AB module light) Q: what does the Logix5555 processor status indicator mean? Answer: the indicator light represents the following table Status light, status light, indicator light The RUN processor is not programmed to run Evergreen processor running The I/O module is not configured in the processor The evergreen is equipped with the I/O module and conforms to reality I/O The green flash is configured with the I/O module, which is not consistent with the actual situation RS232 out of RS232 serial port, no connection communication Green blinking, RS232 serial communication normal BAT processor, battery power, normal The normally red processor has no batteries and changes batteries The evergreen processor is normal and firmware upgrade is complete Red flashing processor is normal and firmware needs updating OK The red processor memory is not compatible with the firmware version. The processor cannot function and contact the vendor Q: what does the 1756-CNB or -CNBR status indicator and status display mean? Answer: can be illustrated by combining the following two tables First, OK lamp and status indicator instruction table Status lamp, status display, reason processing method Modules that do not display power or internal failures are not communicating 1, check the power supply 2, check wiring 3, confirm whether the module is firmly inserted in the frame 4 、 replace module The node address settings for the Msg scrolls module are not set properly True (00 or 99) Reset the node address (01 ~) 98) The BPA# ERR module monitors the blocked slot number by Caused by severe interference on the backplane Replace racks or modules BPRX ERR too many cyclic redundancy check errors Appear by mistake Replace module Hardware fault change module in BPIC ERR module Hardware fault change module in CNIC ERR module Chang Hong There is a repeating node on the DUPL NODE network that resets the module node so that it is in the Unique on the network BACK ERR cannot

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档