- 1、本文档共64页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Quality Control for Standardized Clinical Trials为规范临床试验的质量控制.ppt
The CT Scanner also requires a phantom to be scanned on a daily basis to ensure the proper Hounsfield Units are being applied to structures within the body. Always be sure to center the phantom in all three axes (X,Y, Z). * Each column within the phantom represents a different material simulating different tissue samples. These must be tested on a daily basis to ensure the CT is sending back the proper signal to the detectors. If involved in a clinical trial, the vendor may ask for a daily chart listing of these values. * Uniformity is defined as consistent signals (HUs) and noise measured by ROIs distributed in homogeneous material. * There are many types of CT protocols amongst the imaging community. Do not assume your institution is the same one the vendor endorses! Be sure to check the parameters, length, mAs, kev, and reconstructions. Do not use different CT scanners for the same study, if at all possible. * There are many PET technologists who are not familiar with the kVp, and mAs of an operating system, unless they have been trained by the commercial vendor. The more you know and able to adapt knowledge about your system, the more standardized your images will be. Always check the error logs on a daily basis and report them to the proper personnel. * Your FSE may perform these duties on a routine basis but I personally recommend learning what they are, what they mean, and how to perform them in order to better track and follow thru on artifacts. * The LAP Laser Alignment should be performed monthly and after calibrations. The lasers are mounted on the opposing walls and ceiling. When all X,Y, Z axis lasers are on, they assure proper patient placement on a flat pallet. The patient should be placed as straight as possible so all anatomy is displayed in the same plane. This is critical when undergoing treatment planning. If utilized properly, the patient data may be used for several evaluations which reduces patient radiation and procedure visits. This
您可能关注的文档
- 2010工作总结(薛桂玉)【应用文书例稿】.ppt
- 2012高三数学(大纲版)一轮复习课件:2.5二次函数.ppt
- 第一章_现金流量与资金时间价值.ppt
- HAY-人保公司绩效管理系统培训师培训.ppt
- 《石油化工企业设计防火规范》09.06.27.ppt
- FINANCIAL STATEMENTS - Mercer University美世大学财务报表.ppt
- 创新的节能技术(NCP4303)【企业创新】.ppt
- Vectors & Matrices - UCSD Computer Graphics Lab - Home向量&;矩阵-加州大学圣地亚哥分校的计算机图形实验室的家.ppt
- 小学一年级语文课件《地球爷爷的手》.ppt
- 第一章:物体的平衡第一讲《力 重力 弹力》.ppt
文档评论(0)