Mumma ASHRAE DOAS Filter Louisville Paper穆马ASHRAE DOAS滤波器路易斯维尔纸.pptVIP

Mumma ASHRAE DOAS Filter Louisville Paper穆马ASHRAE DOAS滤波器路易斯维尔纸.ppt

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Mumma ASHRAE DOAS Filter Louisville Paper穆马ASHRAE DOAS滤波器路易斯维尔纸.ppt

Contaminant Transport and Filtration Issues with DOAS Objective Dispel the common perception that DOAS is inferior to all air system when contaminant flushing rates from occupied spaces are considered. Shift the DOAS filter selection paradigm. DOAS Defined Facility floor area and zoning for case study VAV system: Supply air (SA) flow rate, 16,000 cfm, of which 4,000 cfm is OA. Perimeter zones 1 and 2, each receives 1 cfm/ft2 of supply air via a shut off box VAV system. Since the SA is 25% OA, then each perimeter zone is receiving 0.25 cfm/ft2. Interior zone 3 receives 0.6 cfm/ft2 of supply air via a VAV system, i.e. 0.15 cfm/ft2 OA DOAS: OA flow for the facility, 4,000 cfm uniformly distributed in each zone, or 0.20 cfm/ft2. Transient analysis is based upon the following simplifying assumptions: Well mixed zones. No interzonal transfer. Contaminants stay suspended. VAV system is analyzed while operating in the minimum OA mode (4,000 cfm OA), and a supply airflow rate of 16,000 cfm. Releases during full economizer mode (resulting in very high peak space concentrations when releases occur near the OA inlet) will not be presented. The capacitance of the duct system, and its associated influence on the transient response, is neglected. VAV System Schematic DOAS Schematic Transient dimensionless concent’n from release near OA inlet w/ hf = 0% Transient concent’n from release near OA inlet w/ VAV hf = 80% DOAS hf = 98% DOAS filter h necessary to match the space concent’n/exposure after 60 min. for a given VAV filter h. Ref: OA intake occurances. Filter Optimization Assumptions Same SA flows as in transient analysis: VAV 16,000 cfm; and DOAS 4,000 cfm. Assume that the filter loading profile is exponential, causing the average pressure drop over the life of the filter to be: [(Dploaded opt - Dpclean opt)/2]*Fill-ratio. 0.87 Fill-ratio used. Reference replacement frequency is 3 months for VAV and 6 months for DOAS fan/motor combined efficiency, 60%. Electrical

文档评论(0)

cai + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档