- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Introduction to Magnetic Resonance Imaging磁共振成像的介绍
Introduction to Magnetic Resonance Imaging Benjamin M Ellingson, MS Marquette University 21 February 2007 Quantum Theory of Magnetic Resonance Quantum Theory of Magnetic Resonance Quantum Theory of Magnetic Resonance Quantum Theory of Magnetic Resonance So, B0 (static magnetic field) causes some particles to align antiparallel, but most align parallel Classical View: Vector sum of all magnetization is parallel to B0 Theory of Magnetic Resonance Because of the Uncertainty Principle, spins cannot completely align with B0 because the momentum of the particle cannot be defined completely, instead they precess or wobble around B0 at the Larmor Frequency. Theory of Magnetic Resonance Perturb Magnetic Equilibrium By applying a horizontal oscillating field at Larmor frequency (B1) produces a torque on the magnetization vector, M0. Since |B1| |B0| the net field is still in z-dir Causes M0 to “tip” into xy-plane. RF Excitation RF Excitation: Effect of Frequency Relaxation After excitation, if B1 field is turned off the spins undergo relaxation in both transverse and longitudinal directions at different rates. Transverse Relaxation = T2-relaxation = Spin-Spin Relaxation Corresponds to dephasing of neighboring spins Causes decrease in Mxy Longitudinal Relaxation = T1-relaxation = Lattice Relaxation Causes increase in Mz after excitation MR Signal If we have a lot of 1H excited such that they are spinning in phase in the xy-plane (i.e. changing magnetic field) we can detect this with an antenna due to Faraday’s Law of Induction: MR Signal: Free Induction Decay As T2 relaxation occurs (Mxy decreasing), sinusoidal signal at antenna decays with T2 envelope ? Free Induction Decay (FID) Localization via Magnetic Field Gradients In a static magnetic field, we have no way of knowing where MR signal is coming from (i.e. all 1H are precessing at same frequency): Localization via Magnetic Field Gradients To solve this problem we introduce a GRADIENT FIELD Gradient magnetic fields
原创力文档


文档评论(0)