网站大量收购闲置独家精品文档,联系QQ:2885784924

大半径精密离心机可行性研究机械电子工程专业论文.docx

大半径精密离心机可行性研究机械电子工程专业论文.docx

  1. 1、本文档共113页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
大半径精密离心机可行性研究机械电子工程专业论文

Abstract Along with the progress of national defense, and the rapid development of science and technology, technical requirements for navigation of the aircraft, spacecraft, missiles, and so on are increasingly high. And inertial navigation technology with high precision, easy to conceal and good conditions adaptability, not only was widely used in military, but also had played an important role in civil aviation, aerospace, marine and other fields, which attracts world wide attention. As the main sensitive component of the inertial navigation system, the accelerometer directly influences the precision of the navigation system. The precision centrifuge as the main test equipment which calibrates the performance of the accelerometer in the overload condition, the theoretical analysis of the accuracy of its work is particularly important. In this paper, taking the research subject “Feasibility study on a 3.0m large radius precision centrifuge” of State Key Laboratory of Robotics and System (HIT) as the background, analyzes that whether the precision centrifuge can meet the technical requirements. The first expounds the research for the precision centrifuge at home and abroad, and then the factors which influences on the centrifuge acceleration accuracy are analyzed, and the error index is decomposed. The quantitative calculation of acceleration uncertainty is done by the finite element software ansys10.0, and then concludes the theoretical acceleration uncertainty values of the centrifuge which works in the range 0.2g to 30g without the unloading device. The above and below, left and right sides of the initial centrifuge mechanical structure are symmetrical, and then the centrifuge has a symmetrical structure stiffness. In the centrifugal force, the structure deforms linearly. Under the action of angle measuring components and capacitance micro-distance measuring devices which work as auxiliary equipments, the compensation of the dynamic radius and the misalignment a

您可能关注的文档

文档评论(0)

peili2018 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档