臭氧接触池优化集成研究市政工程专业论文.docxVIP

臭氧接触池优化集成研究市政工程专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
臭氧接触池优化集成研究市政工程专业论文

哈尔滨工业大学工学硕士学位论文 哈尔滨工业大学工学硕士学位论文 - - II - Abstract Ozonation has become widely used in drinking water treatment due to ozone’s strong disinfection capability on Cryptosporidium parvum oocysts and Giardia lamblia oocysts, which have strong resistance to chlorine. However, ozonation of bromide-containing water produces bromate, a human carcinogen regulated in China. Ozone contactor design is of crucial importance since disinfection efficiencies are greatly determined by the CT value, and poor contactor design may lead to low hydraulic efficiency and unevenly distributed ozone concentration. Firstly ozone bubble column was taken as the research object,a numerical model was developed based on computational fluid dynamics (CFD) technique which integrated ozone gas-to-liquid phase transfer, diffusion and decay. Bubble column experiments were conducted and results showed that the model could predict the concentration distribution with acceptable accuracy. Secondly the model was applied to optimize contactor configurations based on CT value. Results showed that both guide plates (GP) and horizontal baffles (HB) could improve the CT value, which agreed with the results based on mere hydraulic efficacy, namely T10/HRT. HB improved the CT value by 36.1%, much higher than the 9.4% of GP. However, the combination of GP and HB only achieved 27.9% improvement. The height of HB from the bottom of the tank influenced the effect of HB on CT value. 2.5m was more effective than 2.0m and 3.0m. Finally, a new ozone contactor was developed based on all simulation work. Simulation result showed that the hydraulic efficiency was greatly improved and a plug flow was approximately achieved with T10/HRT being 0.83. Keywords: ozone contactor; optimization; computational fluid dynamics; bubble column - - PAGE IV - 目 录 摘 要 I HYPERLINK \l _bookmark0 Abstract II HYPERLINK \l _bookmark1 目 录 III HYPERLINK \l _bookmark2 第 1 章 绪论 1 HYPERLINK \l _bookmark3 1.1 课题背景及意义 1 HYPERLINK \l _bookmark4 1

文档评论(0)

peili2018 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档