- 1、本文档共56页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
地下水源热泵系统的应用及技术经济分析-建筑与土木工程专业论文
西安建筑科技大学硕士学位论文
西安建筑科技大学硕士学位论文
西安建筑科技大学硕士学位论文
西安建筑科技大学硕士学位论文
The application and techno-economic analysis on ground water heat pumps
Specialty: Architectural and Civil Engineering
Graduate: Pan Xiao
Instructor: Associate Prof. Nan Xiaohong Senior engineer Liu Ying
Abstract
Along with the rapid social and economic development,energy shortages and environmental pollution problems in our country are getting worse.In this case,the air conditioning technology of underground water source heat pump,a kind of green energy saving technology developed.Although the technology was applicated in our country late, but developed very fast.Since it is high of energy efficiency and low pollution,low operating cost, and easy to operate, etc.,it has been used widely in our country.
In this paper, underground water source heat pump air conditioning system is designed for a hospital in xian,The all-year hourly dynamic load and energy consumption simulation analysis were carried out by using the energy consumption simulation software EnergyPlus.The other two system, an soil source heat pump systems and central heating (coal-fired boiler) + water chillers are chosen to make a comparison with the designed at system in annual energy consumption,technology feasibility,economic and environmental impact assessment.The advantages and disadvantages were concluded of each scheme after three aspects of comparative analysis.
Through the simulation results can be concluded that the annual energy consumption of the unit of the underground water source heat pump system is the lowest,converting into a standard coal consumption is 232.78 t,saving 76% than the central heating (coal-fired boiler) + water chiller system,and saving 21% than the soil source heat pump system.
Economic analysis results show that the underground water source heat pump
system is between the central heating (coal-fired boiler) + water chiller system and the soil source heat pump system in economic aspect.It’s annual total cost is
您可能关注的文档
- 分组密码的设计分析及其关键技术的应用应用数学专业论文.docx
- 分组密码的差分故障分析-信息安全专业论文.docx
- 分组密码算法的分析与设计-信息安全专业论文.docx
- 分组教学在中职英语词汇教学中的应用研究-教学(英语)专业论文.docx
- 分组教学在中职英语词汇教学中的应用研究教学(英语)专业论文.docx
- 分组教学模式在农村中学化学课堂教学中的研究——以正安县第六中学高一化学教学为例-学科教学(化学)专业论文.docx
- 分组密码算法和杂凑函数的Grover量子搜索分析-计算机应用技术专业论文.docx
- 分组网同步的硬件时钟与PTP组播实现技术通信与信息系统专业论文.docx
- 分组迭代密码函数的扩散层分析及应用-密码学专业论文.docx
- 分组网精确时钟同步技术的研究与实现-通信与信息系统专业论文.docx
最近下载
- 附件2.安徽省老年大学(学校)建设指导标准(试行).doc
- 《职业素养》知识考试题库(含答案).docx
- DBJ33_T 1321-2024《建筑施工拉杆式悬挑脚手架安全技术规程》.pdf
- 2025年公务员考试时事政治100题及答案(含知识点).docx
- 2024年江西电力职业技术学院单招职业技能测试题库及答案(各地真题).docx VIP
- 新项目方法验证能力确认报告2023简化模板:空气质量 甲醛的测定 乙酰丙酮分光光度法GBT 15516-1995.pdf VIP
- 美的面包机食谱-官方通用版.pdf
- 抗凝剂皮下注射护理规范.pptx VIP
- 学校物业管理服务方案(精选8篇).docx VIP
- 自动控制原理(全套课件1085P).ppt
文档评论(0)