复合式地源热泵系统经济性优化-供热;供燃气;通风及空调工程专业论文
华中科技大学硕士学位论文
华
中
科
技
大
学
硕
士
学
位
论
文
II
II
Abstract
Ground Source Heat Pump uses renewable geothermal energy for cooling and heating, this new technology have a advantage in saving and environmental protection and it is appealed to use in all over the country. he loads are quite imbalance between summer and winter in Wuhan., the average soil temperature will increase in several years’ running. The problem of heat balance plays has a great effect on the total cost in the long run.
In this study a solution to the heat accumulation was proposed Intermittent operation between ground heat exchanger (GHE) and cooling tower can solve this problem .we paid attention to the factors of affect the total cost. We set up a model of an office building in Wuhan and made a Optimization of a Hybrid Ground-Source Heat Pump System in Economic analysis. In addition to the HGSHP system , an extra cooling tower was chosen, whose capacity was equal to the GHE, so that the system can run regularly when the GHE did not work. We wanted to find the best way to reduce the cost in the ten years’ running.
Simulation results showed the exiting fluid temperatures ,the soil average temperature and the total operating costs were lower, the efficiency of heat pump was higher, the heat been rejected to the soil was lower compared to the continuous operation. It is concluded that we could reduce the cost if the system were working in a better condition. The results from this study have some reference value in practical engineering.
Reliability are used in the Hybrid Ground-Source Heat Pump System,The results from
this study also have some reference value in practical engineering.
Key words:Hybrid ground source heat pump Optimization in Economic analysis Matlab Reliability
PAGE IV
PAGE IV
目 录
摘 要 I
Abstract II
1 绪论
1.1 课题的背景 (1)
1.2 研究的目的和意义 (2)
1.3 土壤源热泵间歇运行国内外研究现状 (2)
1.4 课题的研究内容 (5)
1.5 本章小结 (6)
2 复合式地源热泵模型
2.1 建筑负荷模拟 (7)
2.2 热泵机组模型 (10)
2.3 地埋管换热器模型 (11)
2.4 冷却塔模型 (18)
2.5 埋管换热器流体出口温度的确定 (2
您可能关注的文档
- 地铁车厢送风系统性能优化及车厢内CO2扩散规律研究-制冷及低温工程专业论文.docx
- 地铁联络通道冻结法施工数值模拟分析-岩土工程专业论文.docx
- 地铁车站中央空调系统节能控制-控制理论与控制工程专业论文.docx
- 地铁车站人工光环境控制与优化策略研究-系统工程专业论文.docx
- 地铁车站地下连续墙支护深基坑开挖的有限元数值模拟-结构工程专业论文.docx
- 地铁车站地下空间用地权属及价格评估研究-管理科学与工程专业论文.docx
- 地铁车站主体结构内力分布规律及其影响因素研究-建筑与土木工程专业论文.docx
- 地铁车站基坑开挖对周边地表影响的数值分析研究-建筑与土木工程专业论文.docx
- 地铁车站与其上覆建筑物地震响应特性研究-土木工程专业论文.docx
- 地铁车站施工风险管理研究-市政工程专业论文.docx
文档评论(0)