基于IEC 61850的高温超导电缆保护装置分析-电力系统及其自动化专业论文.docxVIP

基于IEC 61850的高温超导电缆保护装置分析-电力系统及其自动化专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
基于IEC 61850的高温超导电缆保护装置分析-电力系统及其自动化专业论文

Abstract High Temperature Superconducting (HTS) cable characterized by large transmission capacity, low loss, no pollution and other significant advantages, provides a new solution to achieve the efficient transmission of large capacity power. HTS cable protection is the key secondary equipment to ensure the safe operation of HTS cable. Driven by the wave of transformation and construction of Digital Substation(DS), research on HTS cable protection applying to DS is of great significance. In this thesis, the development work of HTS cable protection device based on IEC 61850, is carried out, supported by the 110kV cold dielectric HTS cable pilot project of China. According to its technical characteristics, HTS cable will play a great role in addressing the fast growing electric demand. Related technologies and developments of HTS cable and DS are analyzed under the background of development of new technologies in electric system. The main reasons of breakdown in HTS cable system are summarized; and the keys to protect HTS cable are performance analysis of superconducting strip and quench analysis of cable under short current. The comprehensive protection strategy applying to cold dielectric HTS is proposed based on the research of principles of hierarchical protection and differential current protection, and optical fiber temperature protection. On the basis of DS’s technical characteristics and application requirements, the general design scheme of HTS cable protection device based on IEC 61850 is proposed. Given the specification which requires that DS’s protective function does not rely on sync signal, a solution of data synchronization by interpolation according to different point-to-point fiber delays when an external sync signal fails, is raised. In order to exchange information with the refrigeration system, a method compatible with IEC 61850 to transmit nonelectric analog values through GOOSE network is proposed, namely only heartbeating and no rapid repeati

您可能关注的文档

文档评论(0)

131****9843 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档