Outstanding Items for rig acceptance PAGE \* MERGEFORMAT 19 Legend ? OK – Result is acceptable. ? NAC – Result is not acceptable. Test result deviates from the accept criteria and/or test objective (Note: NAC to be used together with CAR or MOD). ? CAR – Corrective action requested. Test result is not in compliance with regulatory requirement or specification. Corrective action is to be taken by Contractor as soon as defined. Test may have to be repeated. ? MOD – Modification requested. Test result may identify needs for modification to system, equipment, tool and/or procedure prior to compliance with drilling operation requirements. ? TBVO – To be verified in operation. Test may not be verified due to practical reasons or not being able to implement modification in due time. ? REC – Recommendation to adjust. Test result within acceptable deviation from specified accept criteria, but to improve operational efficiency and obtain cost saving, adjustment to systems, equipment or procedures can be proposed. 2.2 Visual Inspection 8 Check that all equipment is explosion proof in accordance with the classification of the area. ( Exp. ) CAR 9 Check that this equipment is earthen ( Exp. ) CAR 10 Inspect position and appearance of extinguishers, hydrants, axes, SCBAs CAR M4 Are muster lists/station bills displayed in all accommodation areas? CAR Hazardous zones, electrical equipment Ensure that all equipment permanently placed in hazardous areas is recorded in the PM system and check that regular PM tasks are performed and recorded. Earth bonding records M9 Have sample checks been made of equipment earth bonding conductors to verify the earth continuity path M10 How often is the earthing bonding tested? Check records. 4.12 Watermaker Item Description of Task Acceptance 1 Verify that capacity is as per specification of annex A, in normal drilling mode. Not tested 2 Check if potable water tank is clean (or confirm water quality has been tested) N

文档评论(0)

586334000 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档