Abstract
The poisonous, harmful, combustible and explosive gases generated during the process of petrochemical industry, mineral exploitation, energy development and biotechnology have a strong impact on the environment of atmosphere, living condition and sustainable development ability. Therefore, the real-time concentration detection of these gases is very important. Traditional gas concentration measurement methods complete the real gas concentration detection mission to some extent,but the detecting precision of those methods is low,it can not meet the current needs.In this paper,a novel high accuracy gas concentration measurement system is proposed and studied.The main content includes:
First, the principles of gas absorption, the measurement principle of cavity ring-down and multiple beam interference is researched.
Secondly, a new trace gas concentration measurement system of continuous wave(cw) cavity ring-down spectroscopy(CRDS) is proposed. In this system, the fiber loop based on the Sagnac effects served as a reflector and formed a resonator with a high-reflectivity reflector. It can achieve the reflectivity of the resonator tunable. On this basis, the theoretical analysis and derivation of fiber loop’s Sagnac effect and the measurement principle of cavity ring-down are proposed, meanwhile we can obtain the formula of measurement of the trace gas concentration based on CWCRDS and influence of fiber loop rotational speed to the trace gas concentration measurement system.
Finally, the relationship between reflectivity and fiber loop rotational speed is obtained via the experimental simulation, and so the reflectivity and cavity ring-down graphs. the ring down time of CO2 with different concentration was obtained via experiment, and the results show that with the
II
万方数据
higher concentration, the stronger absorption and the shorter ring-down time. The system filter the noise of photoelectric detector by using mathematical morphology filtering method and the
您可能关注的文档
最近下载
- 公司招聘简章.docx VIP
- 谕兴中学教科研工作总结PPT.pptx VIP
- 数字艺术创作职业技能等级标准(2021年版).pdf VIP
- 2025年《生活饮用水水质处理器卫生安全与功能评价规范——反渗透处理装置.pdf VIP
- 热等静压市场分析报告.pdf VIP
- 中学教科研工作总结PPT.pptx VIP
- 《研学旅行指导师实务》课件——第7章 研学旅行安全管理.pptx VIP
- 健康饮食益处多(教案)-2021-2022学年体育二年级下册 (1).docx VIP
- 压缩空气储能电站接入电网技术规定.pdf VIP
- GA_T 1147-2014 车辆驾驶人员血液酒精含量检验实验室规范.docx VIP
原创力文档


文档评论(0)