CT成像原理介绍英文版;Computed Tomography;X-Ray Discovery ; My name is Godfrey Hounsfield
I work for the Central Research
Labs. of EMI, Ltd in England
I developed the the first clinically
useful CT scanner in 1971; For the first time we could view:;Concept of X-ray Attenuation;How does CT Work?;X-ray goes through
collimator therefore
penetrate only an axial
layer of the object, called
slice;Patient is placed in the center of the measurement field
X-ray is passed through the patient’s slice from many direction along a 360° path
The transmitted beams are captured by the detectors which digitizes these signals
These digitized signals called raw data are sent to a computer which create the CT image
;The object slice is divided into small volume elements called voxels.
Each voxel is assigned a value which is dependent on the average amount of attenuation;The attenuation values are transferred to the computer where they are coded used to create a slice image;CT Generations Design;Slip-ring Technology;Computed Tomography;What is Spiral Scan? -- just 4“C”;Reconstruction of arbitrary
slices (either contiguous or
overlapping) within the
scanned volume
Distance between the
slices is called Increment;;;Increment Slice Thickness
Gaps between slices
Images are further apart
Less images created;;;Computed Tomography;Scan Parameters;Table Speed Pitch ;10mm P1;Scan Range = 300mm;To reduce artifacts due to table motion during spiral scanning,
we use a special reconstruction process called INTERPOLATION;?;PITCH 2;Slice Sensitivity Profile ( SSP );Slice Profile (SP);Factors influencing SSP;Pitch Slice Profile;Slim vs Wide – SSP Comparison;WIDE
720 degree
More photons;Slim - Advantages;Wide - Advantages;Slice Profile Comparison;;Smallest Possible Effective Slice Thickness;Computed Tomography;Peripheral vein eg. antecubital vein
19-20 gauge needle or IV catheter;Tailoring Scan Injection Protocols;;Test Bolus Procedure;Dynamic Evaluation;Computed Tomography;;Sin