Designation:E1453–93(Reapproved2002)e1

StandardGuidefor

StorageofMediathatContainsAnalogorDigital

RadioscopicData1

Thisstandardisissuedunderthe?xeddesignationE1453;thenumberimmediatelyfollowingthedesignationindicatestheyearof

originaladoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.A

superscriptepsilon(e)indicatesaneditorialchangesincethelastrevisionorreapproval.

e1NOTE—MadeeditorialcorrectionstoANSIstandardsinReferencedDocumentsand6.4inDecember2002.

1.Scope

materialsorproductsexamined.Itisfurtherintendedthatthis

guidebeusedasanadjuncttoGuideE1000andPractice

E1255.

3.2Thenecessityforapplyingspeci?ccontrolprocedures

suchasthosedescribedinthisguideisdependenttoacertain

extent,onthedegreetowhichtheuseradherestogood

recordingandstoragepracticesasamatterofroutineproce-

dure.

1.1Thisguidemaybeusedforthecontrolandmaintenance

ofrecordedandunrecordedmagneticandopticalmediaof

analogordigitalelectronicdatafromindustrialradioscopy.

1.2Thisstandarddoesnotpurporttoaddressallofthe

safetyconcerns,ifany,associatedwithitsuse.Itisthe

responsibilityoftheuserofthisstandardtoestablishappro-

priatesafetyandhealthpracticesanddeterminetheapplica-

bilityofregulatorylimitationspriortouse.Forspeci?c

precautionarystatements,seeSection6.

4.UnrecordedMediaStorage

4.1Un-OpenedContainers:

2.ReferencedDocuments

4.1.1StorageRecommendations—Anymediaincontainers

sealedbythemanufacturerandnotopenedshouldbestoredas

shipped,wheneverpossible,toavoidcontainerdamageand

possiblemediadamage.Storagetemperatureshouldbe60°6

20°F(16611°C),relativehumidityrangeof45615%,ata

pressurerangeof12.562.5psiandamaximummagnetic?eld

strengthof50Oe.Theoptimumstorageconditionsare65°F

(18°C)at40%relativehumidity,14.7psiandamaximum

magnetic?eldstrengthof30Oe.Damagingstressesinthe

mediacanbeproducedbylargetemperatureandhumidity

variationsevenif